Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Iowa State University |
---|---|
Assessment Year | 2013 |
Principal Product | metal buildings |
NAICS | 332312 - Fabricated Structural Metal Manufacturing |
SIC | 3449 - Miscellaneous Metal Work |
Sales | $50,000,000-$100,000,000 |
# of Employees | 174 |
Plant Area (Sq.Ft.) | 265,000 |
Annual Production | 33,000 Tons |
Production Hrs. Annual | 6,240 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $285,400 | 3,762,445 | kWh | $0.08 |
Electricity Demand | $98,556 | 12,353 | kW-months/year | $7.98 |
Electricity Fees | $18,861 | - | $ | - |
Natural Gas | $64,789 | 9,011 | MMBtu | $7.19 |
TOTAL ENERGY COSTS | $467,606 | |||
RECOMMENDED SAVINGS* | $54,564 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $22,952 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,004 Cost: $710 |
$1,667 | 21,965 | $337 | 42 | - | - |
$1,667 21,965 kWh |
$337 42 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,170 Cost: $105 |
$1,170 | 15,480 | - | - | - | - |
$1,170 15,480 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,050 Cost: $2,500 |
$1,705 | 22,464 | $345 | 43 | - | - |
$1,705 22,464 kWh |
$345 43 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $413 Cost: $1,388 |
$413 | 5,435 | - | - | - | - |
$413 5,435 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $19,132 Cost: $8,000 |
$15,913 | 209,664 | $3,219 | 403 | - | - |
$15,913 209,664 kWh |
$3,219 403 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $4,973 Cost: $1,700 |
$4,973 | 65,520 | - | - | - | - |
$4,973 65,520 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6221 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY |
Savings: $8,980 Cost: $22,500 |
$6,394 | 84,240 | $2,586 | 324 | - | - |
$6,394 84,240 kWh |
$2,586 324 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $2,461 Cost: $210 |
- | - | - | - | $2,461 | 342 |
- - kWh |
- - kW-months/year |
$2,461 342 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE |
Savings: $280 Cost: $110 |
- | - | - | - | $280 | 39 |
- - kWh |
- - kW-months/year |
$280 39 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $4,264 Cost: $15,781 |
$3,547 | 46,739 | $717 | 90 | - | - |
$3,547 46,739 kWh |
$717 90 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $8,837 Cost: $16,072 |
$7,295 | 96,111 | $1,542 | 193 | - | - |
$7,295 96,111 kWh |
$1,542 193 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $54,564 Cost: $69,076 |
$43,077 | 567,618 | $8,746 | 1,096 | $2,741 | 381 | $43,077 567,618 kWh |
$8,746 1,096 kW-months/year |
$2,741 381 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $22,952 Cost: $35,861 |
$17,895 | 235,770 | $2,596 | 325 | $2,461 | 342 | $17,895 235,770 kWh |
$2,596 325 kW-months/year |
$2,461 342 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |