Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, Kingsville |
---|---|
Assessment Year | 1996 |
Principal Product | Cotton seed oil, lint meal, and hull |
NAICS | n/a |
SIC | 2074 - Cottonseed Oil Mills |
Sales | $10,000,000-$50,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 90,000 Tons |
Production Hrs. Annual | 7,920 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $531,578 | 9,892,732 | kWh | $0.05 |
Electricity Demand | $261,234 | 20,277 | kW-months/year | $12.88 |
Electricity Fees | $9,097 | - | $ | - |
TOTAL ENERGY COSTS | $1,243,734 | |||
RECOMMENDED SAVINGS* | $641,529 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $503,515 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $134,608 Cost: $2,000,000 |
$327,304 | 14,400,645 | - | - | $(-192,696) | (-57,350) | - | - | - | - |
$327,304 14,400,645 kWh |
- - kW-months/year |
$(-192,696) (-57,350) MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $33,535 Cost: $15,675 |
$17,876 | 732,708 | $15,659 | 1,110 | - | - | - | - | - | - |
$17,876 732,708 kWh |
$15,659 1,110 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $26,966 Cost: $37,100 |
$14,718 | 603,165 | $12,248 | 868 | - | - | - | - | - | - |
$14,718 603,165 kWh |
$12,248 868 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $3,406 Cost: $12,000 |
$3,119 | 58,910 | $287 | 20 | - | - | - | - | - | - |
$3,119 58,910 kWh |
$287 20 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $722 Cost: $1,230 |
$722 | 29,601 | - | - | - | - | - | - | - | - |
$722 29,601 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $467 Cost: $194 |
$467 | 7,327 | - | - | - | - | - | - | - | - |
$467 7,327 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.1192 REDUCE SCRAP PRODUCTION |
Savings: $414,056 Cost: $1,500 |
- | - | - | - | - | - | - | - | $414,056 | 4,153,270 |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$414,056 4,153,270 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5131 RECYCLE WHITE WATER |
Savings: $27,769 Cost: $2,930 |
- | - | - | - | - | - | $27,769 | 1,673,000 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$27,769 1,673,000 Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $641,529 Cost: $2,070,629 |
$364,206 | 15,832,356 | $28,194 | 1,998 | $(-192,696) | (-57,350) | $27,769 | 1,673,000 | $414,056 | 4,153,270 | $364,206 15,832,356 kWh |
$28,194 1,998 kW-months/year |
$(-192,696) (-57,350) MMBtu |
$27,769 1,673,000 Tgal |
$414,056 4,153,270 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $503,515 Cost: $58,629 |
$33,783 | 1,372,801 | $27,907 | 1,978 | - | - | $27,769 | 1,673,000 | $414,056 | 4,153,270 | $33,783 1,372,801 kWh |
$27,907 1,978 kW-months/year |
- - MMBtu |
$27,769 1,673,000 Tgal |
$414,056 4,153,270 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) |