Select a Center

Arizona State University
Boise State University
Case Western Reserve University
Clemson University
Colorado State University
Georgia Institute of Technology
Indiana University-Purdue University
Lehigh University
Louisiana State University
North Carolina State
Oklahoma State University
Oregon State University
San Diego State University
San Francisco State University
Syracuse University
Tennessee Technological University
Texas A&M, College Station
University of Alabama
University of Dayton
University of Delaware
University of Florida
University of Illinois, Chicago
University of Kentucky
University of Massachusetts
University of Miami
University of Missouri-Columbia
University of Nebraska–Lincoln
University of Texas Rio Grande Valley
University of Utah
University of Wisconsin, Milwaukee
West Virginia University
IAC logo
IAC Assessment: LE0228
Sponsored by:
EERE AMO
IAC logo
IAC Assessment: LE0228
Due to University and State restrictions, IAC assessment activities at your local center may be on hold.
Contact your local center for more details on operating status and available services.

Click here for details about Coronavirus (COVID-19) Recovery Support programs
IAC Center Lehigh University
Assessment Year 2006
Principal Product Electronic components
NAICS 334416 - Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing
SIC 3675 - Electronic Capacitors
Sales $14,000,000
# of Employees 96
Plant Area (Sq.Ft.) 50,000
Annual Production 0 Units
Production Hrs. Annual 6,120
Location (State) NJ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $227,565 2,536,292 kWh $0.09
Electricity Demand $48,682 8,790 kW-months/year $5.54
TOTAL ENERGY COSTS $276,247
RECOMMENDED SAVINGS* $34,435 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $13,189
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Electricity Usage Electricity Demand Electricity Fees
$ kWh $ kW-months/year $ $
01: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$15,075
Cost:
$41,200
$12,038 133,760 $3,037 548 - - $12,038
133,760
kWh
$3,037
548
kW-months/year
-
-
$
02: 2.3134 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION Savings:
$4,308
Cost:
$620
- - $4,308 778 - - -
-
kWh
$4,308
778
kW-months/year
-
-
$
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$3,963
Cost:
$1,250
$3,963 44,158 - - - - $3,963
44,158
kWh
-
-
kW-months/year
-
-
$
04: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$2,427
Cost:
$2,500
- - $2,427 438 - - -
-
kWh
$2,427
438
kW-months/year
-
-
$
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,503
Cost:
$100
$1,104 12,264 $399 72 - - $1,104
12,264
kWh
$399
72
kW-months/year
-
-
$
06: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$988
Cost:
$1,700
$616 6,846 $372 67 - - $616
6,846
kWh
$372
67
kW-months/year
-
-
$
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$315
Cost:
$750
$210 2,328 $105 19 - - $210
2,328
kWh
$105
19
kW-months/year
-
-
$
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,856
Cost:
$43,904
$4,379 48,654 $529 95 $948 - $4,379
48,654
kWh
$529
95
kW-months/year
$948
-
$
TOTAL RECOMMENDED Savings:
$34,435
Cost:
$92,024
$22,310 248,010 $11,177 2,017 $948 - $22,310
248,010
kWh
$11,177
2,017
kW-months/year
$948
-
$
TOTAL IMPLEMENTED Savings:
$13,189
Cost:
$6,170
$5,683 63,268 $7,506 1,355 - - $5,683
63,268
kWh
$7,506
1,355
kW-months/year
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Electricity Fees Electricity Usage Electricity Demand Electricity Fees