Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2006 |
Principal Product | solar cells and solar panels |
NAICS | 334413 - Semiconductor and Related Device Manufacturing |
SIC | 3674 - Semiconductors And Related Devices |
Sales | $50,000,000-$100,000,000 |
# of Employees | 306 |
Plant Area (Sq.Ft.) | 135,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 6,240 |
Location (State) | DE |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $483,121 | 13,861,638 | kWh | $0.03 |
Electricity Demand | $351,163 | 58,369 | kW-months/year | $6.02 |
Natural Gas | $93,559 | 7,415 | MMBtu | $12.62 |
TOTAL ENERGY COSTS | $927,843 | |||
RECOMMENDED SAVINGS* | $401,942 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $305,382 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Water Consumption | Increase in Production | Electricity Usage | Electricity Demand | Personnel Changes | Water Consumption | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $265,405 Cost: $500,000 |
- | - | - | - | $94,112 | - | $36,176 | - | $135,117 | - |
- - kWh |
- - kW-months/year |
$94,112 - $ |
$36,176 - Tgal |
$135,117 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7233 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT |
Savings: $74,790 Cost: $800 |
$54,343 | 1,552,666 | $20,447 | 3,396 | - | - | - | - | - | - |
$54,343 1,552,666 kWh |
$20,447 3,396 kW-months/year |
- - $ |
- - Tgal |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $18,974 Cost: $2,092 |
$13,911 | 397,452 | $5,063 | 841 | - | - | - | - | - | - |
$13,911 397,452 kWh |
$5,063 841 kW-months/year |
- - $ |
- - Tgal |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $8,308 Cost: $2,500 |
- | - | $8,308 | 1,380 | - | - | - | - | - | - |
- - kWh |
$8,308 1,380 kW-months/year |
- - $ |
- - Tgal |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $7,178 Cost: $4,500 |
$5,394 | 154,104 | $1,784 | 296 | - | - | - | - | - | - |
$5,394 154,104 kWh |
$1,784 296 kW-months/year |
- - $ |
- - Tgal |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,994 Cost: $500 |
$4,000 | 114,292 | $994 | 165 | - | - | - | - | - | - |
$4,000 114,292 kWh |
$994 165 kW-months/year |
- - $ |
- - Tgal |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $331 Cost: $300 |
$262 | 7,492 | $69 | 11 | - | - | - | - | - | - |
$262 7,492 kWh |
$69 11 kW-months/year |
- - $ |
- - Tgal |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.1131 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC |
Savings: $192 Cost: $300 |
$192 | 5,511 | - | - | - | - | - | - | - | - |
$192 5,511 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $21,770 Cost: $139,872 |
$16,359 | 467,401 | $5,411 | 899 | - | - | - | - | - | - |
$16,359 467,401 kWh |
$5,411 899 kW-months/year |
- - $ |
- - Tgal |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $401,942 Cost: $650,864 |
$94,461 | 2,698,918 | $42,076 | 6,988 | $94,112 | - | $36,176 | - | $135,117 | - | $94,461 2,698,918 kWh |
$42,076 6,988 kW-months/year |
$94,112 - $ |
$36,176 - Tgal |
$135,117 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $305,382 Cost: $510,192 |
$23,759 | 678,851 | $16,218 | 2,693 | $94,112 | - | $36,176 | - | $135,117 | - | $23,759 678,851 kWh |
$16,218 2,693 kW-months/year |
$94,112 - $ |
$36,176 - Tgal |
$135,117 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Water Consumption | Increase in Production | Electricity Usage | Electricity Demand | Personnel Changes | Water Consumption | Increase in Production |