Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2008 |
Principal Product | bottled water |
NAICS | 312112 - Bottled Water Manufacturing |
SIC | 2086 - Bottled And Canned Soft Drinks |
Sales | $50,000,000-$100,000,000 |
# of Employees | 322 |
Plant Area (Sq.Ft.) | 385,000 |
Annual Production | 454,272,000 Units |
Production Hrs. Annual | 8,736 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $3,613,312 | 70,230,247 | kWh | $0.05 |
Electricity Demand | $823,235 | 117,030 | kW-months/year | $7.03 |
Natural Gas | $816,078 | 98,061 | MMBtu | $8.32 |
TOTAL ENERGY COSTS | $5,252,625 | |||
RECOMMENDED SAVINGS* | $390,992 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $136,305 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $198,263 Cost: $200,000 |
$142,338 | 2,790,945 | $25,266 | 3,594 | - | - | $30,659 | - |
$142,338 2,790,945 kWh |
$25,266 3,594 kW-months/year |
- - MMBtu |
$30,659 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $41,140 Cost: $6,000 |
- | - | $41,140 | 5,852 | - | - | - | - |
- - kWh |
$41,140 5,852 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $36,169 Cost: $30,000 |
$30,411 | 596,286 | $5,758 | 819 | - | - | - | - |
$30,411 596,286 kWh |
$5,758 819 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $31,944 Cost: $2,000 |
- | - | - | - | $31,944 | 3,839 | - | - |
- - kWh |
- - kW-months/year |
$31,944 3,839 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT |
Savings: $21,795 Cost: $30,000 |
- | - | - | - | $21,795 | 2,620 | - | - |
- - kWh |
- - kW-months/year |
$21,795 2,620 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.5195 CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS |
Savings: $26,495 Cost: $31,435 |
$22,277 | 436,800 | $4,218 | 600 | - | - | - | - |
$22,277 436,800 kWh |
$4,218 600 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $9,200 Cost: $3,000 |
- | - | - | - | $9,200 | 1,106 | - | - |
- - kWh |
- - kW-months/year |
$9,200 1,106 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $8,134 Cost: $1,500 |
$6,720 | 131,763 | $1,414 | 201 | - | - | - | - |
$6,720 131,763 kWh |
$1,414 201 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,723 Cost: $1,000 |
$3,971 | 77,870 | $752 | 107 | - | - | - | - |
$3,971 77,870 kWh |
$752 107 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $13,129 Cost: $300,000 |
$11,090 | 211,411 | $2,039 | 290 | - | - | - | - |
$11,090 211,411 kWh |
$2,039 290 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $390,992 Cost: $604,935 |
$216,807 | 4,245,075 | $80,587 | 11,463 | $62,939 | 7,565 | $30,659 | - | $216,807 4,245,075 kWh |
$80,587 11,463 kW-months/year |
$62,939 7,565 MMBtu |
$30,659 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $136,305 Cost: $342,000 |
$45,472 | 885,567 | $49,689 | 7,068 | $41,144 | 4,945 | - | - | $45,472 885,567 kWh |
$49,689 7,068 kW-months/year |
$41,144 4,945 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost |