Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2003 |
Principal Product | Fluid valves |
NAICS | 333995 - Fluid Power Cylinder and Actuator Manufacturing |
SIC | 3593 - Fluid Power Cylinders & Actuators |
Sales | $1,000,000-$5,000,000 |
# of Employees | 25 |
Plant Area (Sq.Ft.) | 30,000 |
Annual Production | 20,000 Pieces |
Production Hrs. Annual | 2,600 |
Location (State) | AR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Natural Gas | $1,583 | 206 | MMBtu | $7.68 |
TOTAL ENERGY COSTS | $1,583 | |||
RECOMMENDED SAVINGS* | $7,211 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,091 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3137 USE POWER DURING OFF-PEAK PERIODS |
Savings: $3,779 Cost: - |
- | - | $3,542 | 1,476 | $237 | - | - | - | - | - | - | - |
- - kWh |
$3,542 1,476 kW-months/year |
$237 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,025 Cost: $112 |
$654 | 9,631 | $307 | 128 | $64 | - | - | - | - | - | - | - |
$654 9,631 kWh |
$307 128 kW-months/year |
$64 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $848 Cost: $90 |
$644 | 9,489 | $151 | 63 | $53 | - | - | - | - | - | - | - |
$644 9,489 kWh |
$151 63 kW-months/year |
$53 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $578 Cost: $196 |
$369 | 5,434 | $173 | 72 | $36 | - | - | - | - | - | - | - |
$369 5,434 kWh |
$173 72 kW-months/year |
$36 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $360 Cost: $140 |
$186 | 2,733 | - | - | $12 | - | - | - | $73 | - | $89 | - |
$186 2,733 kWh |
- - kW-months/year |
$12 - $ |
- - MMBtu |
$73 - $ |
$89 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $292 Cost: $191 |
- | - | - | - | $18 | - | $274 | 38 | - | - | - | - |
- - kWh |
- - kW-months/year |
$18 - $ |
$274 38 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $130 Cost: $80 |
$122 | 1,798 | - | - | $8 | - | - | - | - | - | - | - |
$122 1,798 kWh |
- - kW-months/year |
$8 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $113 Cost: $40 |
$94 | 1,382 | $12 | 5 | $7 | - | - | - | - | - | - | - |
$94 1,382 kWh |
$12 5 kW-months/year |
$7 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $86 Cost: $90 |
$81 | 1,199 | - | - | $5 | - | - | - | - | - | - | - |
$81 1,199 kWh |
- - kW-months/year |
$5 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $7,211 Cost: $939 |
$2,150 | 31,666 | $4,185 | 1,744 | $440 | - | $274 | 38 | $73 | - | $89 | - | $2,150 31,666 kWh |
$4,185 1,744 kW-months/year |
$440 - $ |
$274 38 MMBtu |
$73 - $ |
$89 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,091 Cost: $210 |
$860 | 12,669 | $163 | 68 | $68 | - | - | - | - | - | - | - | $860 12,669 kWh |
$163 68 kW-months/year |
$68 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Ancillary Material Cost |