Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2003 |
Principal Product | Steel Fabrication |
NAICS | 332312 - Fabricated Structural Metal Manufacturing |
SIC | 3441 - Fabricated Structural Metal |
Sales | $10,000,000-$50,000,000 |
# of Employees | 90 |
Plant Area (Sq.Ft.) | 250,000 |
Annual Production | 12,000 Tons |
Production Hrs. Annual | 3,640 |
Location (State) | AR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $72,096 | 2,482,836 | kWh | $0.03 |
Electricity Demand | $76,871 | 9,070 | kW-months/year | $8.48 |
Electricity Fees | $10,817 | - | $ | - |
Natural Gas | $49,202 | 5,843 | MMBtu | $8.42 |
TOTAL ENERGY COSTS | $208,986 | |||
RECOMMENDED SAVINGS* | $61,444 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $37,889 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $31,185 Cost: $1,605 |
$13,960 | 480,730 | $15,103 | 1,742 | $2,122 | - | - | - |
$13,960 480,730 kWh |
$15,103 1,742 kW-months/year |
$2,122 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3137 USE POWER DURING OFF-PEAK PERIODS |
Savings: $16,056 Cost: - |
- | - | $14,962 | 1,728 | $1,094 | - | - | - |
- - kWh |
$14,962 1,728 kW-months/year |
$1,094 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7145 INSTALL SKYLIGHTS |
Savings: $6,266 Cost: $4,116 |
$2,927 | 100,800 | $2,913 | 336 | $426 | - | - | - |
$2,927 100,800 kWh |
$2,913 336 kW-months/year |
$426 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,298 Cost: $6,000 |
$4,938 | 170,034 | - | - | $360 | - | - | - |
$4,938 170,034 kWh |
- - kW-months/year |
$360 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $1,406 Cost: $159 |
- | - | - | - | - | - | $1,406 | - |
- - kWh |
- - kW-months/year |
- - $ |
$1,406 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,233 Cost: $700 |
$397 | 13,666 | - | - | $29 | - | $807 | - |
$397 13,666 kWh |
- - kW-months/year |
$29 - $ |
$807 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $61,444 Cost: $12,580 |
$22,222 | 765,230 | $32,978 | 3,806 | $4,031 | - | $2,213 | - | $22,222 765,230 kWh |
$32,978 3,806 kW-months/year |
$4,031 - $ |
$2,213 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $37,889 Cost: $7,764 |
$18,898 | 650,764 | $15,103 | 1,742 | $2,482 | - | $1,406 | - | $18,898 650,764 kWh |
$15,103 1,742 kW-months/year |
$2,482 - $ |
$1,406 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes |