Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisiana, Lafayette
Assessment Year 2003
Principal Product Steel Fabrication
NAICS 332312 - Fabricated Structural Metal Manufacturing
SIC 3441 - Fabricated Structural Metal
Sales $10,000,000-$50,000,000
# of Employees 90
Plant Area (Sq.Ft.) 250,000
Annual Production 12,000 Tons
Production Hrs. Annual 3,640
Location (State) AR
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $72,096 2,482,836 kWh $0.03
Electricity Demand $76,871 9,070 kW-months/year $8.48
Electricity Fees $10,817 - $ -
Natural Gas $49,202 5,843 MMBtu $8.42
TOTAL ENERGY COSTS $208,986
RECOMMENDED SAVINGS* $61,444 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $37,889
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Personnel Changes Electricity Usage Electricity Demand Electricity Fees Personnel Changes
$ kWh $ kW-months/year $ $ $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$31,185
Cost:
$1,605
$13,960 480,730 $15,103 1,742 $2,122 - - - $13,960
480,730
kWh
$15,103
1,742
kW-months/year
$2,122
-
$
-
-
$
02: 2.3137 USE POWER DURING OFF-PEAK PERIODS Savings:
$16,056
Cost:
-
- - $14,962 1,728 $1,094 - - - -
-
kWh
$14,962
1,728
kW-months/year
$1,094
-
$
-
-
$
03: 2.7145 INSTALL SKYLIGHTS Savings:
$6,266
Cost:
$4,116
$2,927 100,800 $2,913 336 $426 - - - $2,927
100,800
kWh
$2,913
336
kW-months/year
$426
-
$
-
-
$
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$5,298
Cost:
$6,000
$4,938 170,034 - - $360 - - - $4,938
170,034
kWh
-
-
kW-months/year
$360
-
$
-
-
$
05: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE Savings:
$1,406
Cost:
$159
- - - - - - $1,406 - -
-
kWh
-
-
kW-months/year
-
-
$
$1,406
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,233
Cost:
$700
$397 13,666 - - $29 - $807 - $397
13,666
kWh
-
-
kW-months/year
$29
-
$
$807
-
$
TOTAL RECOMMENDED Savings:
$61,444
Cost:
$12,580
$22,222 765,230 $32,978 3,806 $4,031 - $2,213 - $22,222
765,230
kWh
$32,978
3,806
kW-months/year
$4,031
-
$
$2,213
-
$
TOTAL IMPLEMENTED Savings:
$37,889
Cost:
$7,764
$18,898 650,764 $15,103 1,742 $2,482 - $1,406 - $18,898
650,764
kWh
$15,103
1,742
kW-months/year
$2,482
-
$
$1,406
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $
Electricity Usage Electricity Demand Electricity Fees Personnel Changes Electricity Usage Electricity Demand Electricity Fees Personnel Changes