Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2005 |
Principal Product | Soybean milling |
NAICS | 311212 - Rice Milling |
SIC | 2044 - Rice Milling |
Sales | $100,000,000-$500,000,000 |
# of Employees | 280 |
Plant Area (Sq.Ft.) | 285,000 |
Annual Production | 45,000,000 Pounds |
Production Hrs. Annual | 8,736 |
Location (State) | AR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,020,194 | 52,710,092 | kWh | $0.02 |
Electricity Demand | $998,177 | 92,544 | kW-months/year | $10.79 |
Electricity Fees | $80,942 | - | $ | - |
Natural Gas | $1,607,095 | 288,216 | MMBtu | $5.58 |
TOTAL ENERGY COSTS | $3,706,408 | |||
RECOMMENDED SAVINGS* | $174,770 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $122,756 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $56,386 Cost: $73,240 |
$54,217 | 2,801,924 | - | - | $2,169 | - | - | - |
$54,217 2,801,924 kWh |
- - kW-months/year |
$2,169 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $38,693 Cost: - |
- | - | - | - | - | - | $38,693 | 6,312 |
- - kWh |
- - kW-months/year |
- - $ |
$38,693 6,312 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $17,619 Cost: $14,000 |
$16,941 | 875,513 | - | - | $678 | - | - | - |
$16,941 875,513 kWh |
- - kW-months/year |
$678 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3135 SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS |
Savings: $17,072 Cost: $2,900 |
- | - | - | - | - | - | $17,072 | 2,785 |
- - kWh |
- - kW-months/year |
- - $ |
$17,072 2,785 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $15,391 Cost: $2,800 |
$8,454 | 436,916 | $6,345 | 588 | $592 | - | - | - |
$8,454 436,916 kWh |
$6,345 588 kW-months/year |
$592 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $13,837 Cost: $3,400 |
$7,543 | 389,826 | $5,762 | 534 | $532 | - | - | - |
$7,543 389,826 kWh |
$5,762 534 kW-months/year |
$532 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $7,454 Cost: - |
- | - | - | - | - | - | $7,454 | 1,216 |
- - kWh |
- - kW-months/year |
- - $ |
$7,454 1,216 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $4,107 Cost: - |
- | - | - | - | - | - | $4,107 | 670 |
- - kWh |
- - kW-months/year |
- - $ |
$4,107 670 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $2,451 Cost: $450 |
$2,357 | 121,785 | - | - | $94 | - | - | - |
$2,357 121,785 kWh |
- - kW-months/year |
$94 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,243 Cost: - |
$1,196 | 61,806 | - | - | $47 | - | - | - |
$1,196 61,806 kWh |
- - kW-months/year |
$47 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $517 Cost: - |
$497 | 25,702 | - | - | $20 | - | - | - |
$497 25,702 kWh |
- - kW-months/year |
$20 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $174,770 Cost: $96,790 |
$91,205 | 4,713,472 | $12,107 | 1,122 | $4,132 | - | $67,326 | 10,983 | $91,205 4,713,472 kWh |
$12,107 1,122 kW-months/year |
$4,132 - $ |
$67,326 10,983 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $122,756 Cost: $96,790 |
$89,512 | 4,625,964 | $12,107 | 1,122 | $4,065 | - | $17,072 | 2,785 | $89,512 4,625,964 kWh |
$12,107 1,122 kW-months/year |
$4,065 - $ |
$17,072 2,785 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |