Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Loyola Marymount University |
---|---|
Assessment Year | 2001 |
Principal Product | heat treatment jobshop |
NAICS | n/a |
SIC | 3398 - Metal Heat Treating |
Sales | $1,000,000-$5,000,000 |
# of Employees | 48 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 803,250 Pieces |
Production Hrs. Annual | 7,112 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $224,659 | 4,669,557 | kWh | $0.05 |
Electricity Demand | $120,750 | 34,596 | kW-months/year | $3.49 |
Electricity Fees | $18,213 | - | $ | - |
Natural Gas | $182,314 | 26,822 | MMBtu | $6.80 |
TOTAL ENERGY COSTS | $545,936 | |||
RECOMMENDED SAVINGS* | $47,993 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $23,484 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7145 INSTALL SKYLIGHTS |
Savings: $2,320 Cost: $1,700 |
$2,320 | 19,621 | - | - | - | - | - | - | - | - |
$2,320 19,621 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $9,287 Cost: $8,000 |
- | - | - | - | $9,287 | 1,156 | - | - | - | - |
- - kWh |
- - kW-months/year |
$9,287 1,156 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $377 Cost: $111 |
$331 | 3,033 | $46 | 31 | - | - | - | - | - | - |
$331 3,033 kWh |
$46 31 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.426 MODIFY WORKLOAD |
Savings: $10,144 Cost: $3,750 |
- | - | - | - | - | - | $10,144 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$10,144 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.423 MOVE PRODUCT USING MECHANICAL MEANS |
Savings: $1,838 Cost: $3,350 |
- | - | - | - | - | - | - | - | $1,838 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$1,838 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.431 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY |
Savings: $1,838 Cost: $3,296 |
- | - | - | - | - | - | $1,838 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,838 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.122 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS |
Savings: $22,189 Cost: $16,860 |
- | - | - | - | - | - | $22,189 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$22,189 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $47,993 Cost: $37,067 |
$2,651 | 22,654 | $46 | 31 | $9,287 | 1,156 | $34,171 | - | $1,838 | - | $2,651 22,654 kWh |
$46 31 kW-months/year |
$9,287 1,156 MMBtu |
$34,171 - $ |
$1,838 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $23,484 Cost: $18,507 |
$331 | 3,033 | $46 | 31 | $9,287 | 1,156 | $11,982 | - | $1,838 | - | $331 3,033 kWh |
$46 31 kW-months/year |
$9,287 1,156 MMBtu |
$11,982 - $ |
$1,838 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Product |