IAC logo
IAC Assessment: LM0015
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: LM0015
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Loyola Marymount University
Assessment Year 2001
Principal Product double diaphragm pumps
NAICS n/a
SIC 3561 - Pumps And Pumping Equipment
Sales $50,000,000-$100,000,000
# of Employees 235
Plant Area (Sq.Ft.) 157,216
Annual Production 84,000 Pieces
Production Hrs. Annual 5,161
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $316,872 6,688,566 kWh $0.05
Electricity Demand $150,301 34,456 kW-months/year $4.36
Electricity Fees $24,374 - $ -
Natural Gas $12,377 1,484 MMBtu $8.34
TOTAL ENERGY COSTS $503,924
RECOMMENDED SAVINGS* $487,476 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $142,830
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Personnel Changes Administrative Changes Electricity Usage Electricity Demand Personnel Changes Administrative Changes
$ kWh $ kW-months/year $ $ $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$10,371
Cost:
$19,200
$8,501 85,466 $1,870 199 - - - - $8,501
85,466
kWh
$1,870
199
kW-months/year
-
-
$
-
-
$
02: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT Savings:
$5,951
Cost:
$550
$5,004 36,757 $947 89 - - - - $5,004
36,757
kWh
$947
89
kW-months/year
-
-
$
-
-
$
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$6,264
Cost:
$800
$4,960 44,126 $1,304 108 - - - - $4,960
44,126
kWh
$1,304
108
kW-months/year
-
-
$
-
-
$
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$5,982
Cost:
-
$4,904 49,298 $1,078 115 - - - - $4,904
49,298
kWh
$1,078
115
kW-months/year
-
-
$
-
-
$
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$30,965
Cost:
$12,950
$24,506 217,908 $6,459 504 - - - - $24,506
217,908
kWh
$6,459
504
kW-months/year
-
-
$
-
-
$
06: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$100,699
Cost:
$450
- - - - - - $100,699 - -
-
kWh
-
-
kW-months/year
-
-
$
$100,699
-
$
07: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS Savings:
$8,944
Cost:
$11,800
- - - - - - $8,944 - -
-
kWh
-
-
kW-months/year
-
-
$
$8,944
-
$
08: 4.3110 SCHEDULE DELIVERIES ACCORDING TO DEMAND Savings:
$207,000
Cost:
$1,000
- - - - - - $207,000 - -
-
kWh
-
-
kW-months/year
-
-
$
$207,000
-
$
09: 4.6120 CONTRACT OUT MAINTENANCE Savings:
$7,300
Cost:
-
- - - - $7,300 - - - -
-
kWh
-
-
kW-months/year
$7,300
-
$
-
-
$
10: 4.1310 MODIFY PROCESS TO REDUCE MATERIAL USE/COST Savings:
$104,000
Cost:
$24,000
- - - - $104,000 - - - -
-
kWh
-
-
kW-months/year
$104,000
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$487,476
Cost:
$70,750
$47,875 433,555 $11,658 1,015 $111,300 - $316,643 - $47,875
433,555
kWh
$11,658
1,015
kW-months/year
$111,300
-
$
$316,643
-
$
TOTAL IMPLEMENTED Savings:
$142,830
Cost:
$56,350
$18,465 166,349 $4,121 396 $111,300 - $8,944 - $18,465
166,349
kWh
$4,121
396
kW-months/year
$111,300
-
$
$8,944
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $
Electricity Usage Electricity Demand Personnel Changes Administrative Changes Electricity Usage Electricity Demand Personnel Changes Administrative Changes