Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Loyola Marymount University |
---|---|
Assessment Year | 2002 |
Principal Product | envelopes |
NAICS | n/a |
SIC | 2677 - Envelopes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 166 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 2,147,483,647 Pieces |
Production Hrs. Annual | 6,000 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $444,811 | 5,373,576 | kWh | $0.08 |
Electricity Demand | $158,235 | 35,076 | kW-months/year | $4.51 |
Electricity Fees | $29,735 | - | $ | - |
TOTAL ENERGY COSTS | $632,781 | |||
RECOMMENDED SAVINGS* | $179,309 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $49,592 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $2,166 Cost: $1,152 |
$1,758 | 15,506 | $408 | 31 | - | - | - | - |
$1,758 15,506 kWh |
$408 31 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7145 INSTALL SKYLIGHTS |
Savings: $6,152 Cost: $4,400 |
$5,012 | 37,222 | $1,140 | 86 | - | - | - | - |
$5,012 37,222 kWh |
$1,140 86 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $36,384 Cost: $900 |
$30,071 | 265,244 | $7,093 | 530 | $(-780) | - | - | - |
$30,071 265,244 kWh |
$7,093 530 kW-months/year |
$(-780) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $494 Cost: $250 |
$400 | 3,531 | $94 | 7 | - | - | - | - |
$400 3,531 kWh |
$94 7 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $4,396 Cost: - |
$3,558 | 31,385 | $838 | 62 | - | - | - | - |
$3,558 31,385 kWh |
$838 62 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.321 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES |
Savings: $66,667 Cost: - |
- | - | - | - | - | - | $66,667 | - |
- - kWh |
- - kW-months/year |
- - $ |
$66,667 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.625 DEVELOP STANDARD OPERATING PROCEDURES |
Savings: $63,050 Cost: $12,200 |
- | - | - | - | $63,050 | - | - | - |
- - kWh |
- - kW-months/year |
$63,050 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $179,309 Cost: $18,902 |
$40,799 | 352,888 | $9,573 | 716 | $62,270 | - | $66,667 | - | $40,799 352,888 kWh |
$9,573 716 kW-months/year |
$62,270 - $ |
$66,667 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $49,592 Cost: $6,702 |
$40,799 | 352,888 | $9,573 | 716 | $(-780) | - | - | - | $40,799 352,888 kWh |
$9,573 716 kW-months/year |
$(-780) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes |