Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Loyola Marymount University |
---|---|
Assessment Year | 2002 |
Principal Product | plastic film |
NAICS | n/a |
SIC | 3081 - Unsupported Plastics Film & Sheet |
Sales | $50,000,000-$100,000,000 |
# of Employees | 185 |
Plant Area (Sq.Ft.) | 122,000 |
Annual Production | 75,000,000 Pounds |
Production Hrs. Annual | 8,520 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,749,487 | 25,802,712 | kWh | $0.07 |
Electricity Demand | $447,343 | 43,284 | kW-months/year | $10.34 |
Electricity Fees | $110,501 | - | $ | - |
Natural Gas | $750 | 67 | MMBtu | $11.19 |
TOTAL ENERGY COSTS | $2,308,081 | |||
RECOMMENDED SAVINGS* | $43,199 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $26,562 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Electricity Usage | Electricity Demand | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $20,645 Cost: $300 |
$18,072 | 183,434 | $2,573 | 251 | - | - |
$18,072 183,434 kWh |
$2,573 251 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $6,353 Cost: $1,480 |
$4,266 | 43,297 | $2,087 | 204 | - | - |
$4,266 43,297 kWh |
$2,087 204 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,937 Cost: $200 |
$4,113 | 41,758 | $604 | 59 | $(-780) | - |
$4,113 41,758 kWh |
$604 59 kW-months/year |
$(-780) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $3,911 Cost: - |
$3,411 | 34,623 | $500 | 49 | - | - |
$3,411 34,623 kWh |
$500 49 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $2,006 Cost: $2,640 |
$1,756 | 17,823 | $250 | 24 | - | - |
$1,756 17,823 kWh |
$250 24 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $6,347 Cost: $900 |
$5,527 | 56,097 | $820 | 79 | - | - |
$5,527 56,097 kWh |
$820 79 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $43,199 Cost: $5,520 |
$37,145 | 377,032 | $6,834 | 666 | $(-780) | - | $37,145 377,032 kWh |
$6,834 666 kW-months/year |
$(-780) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $26,562 Cost: $2,940 |
$23,239 | 235,880 | $3,323 | 324 | - | - | $23,239 235,880 kWh |
$3,323 324 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Electricity Usage | Electricity Demand | Personnel Changes |