Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Loyola Marymount University |
---|---|
Assessment Year | 2006 |
Principal Product | Lead acid batteries |
NAICS | 335911 - Storage Battery Manufacturing |
SIC | 3691 - Storage Batteries |
Sales | $50,000,000-$100,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 160,000 |
Annual Production | 2,400,000 Pieces |
Production Hrs. Annual | 6,600 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,319,705 | 21,746,532 | kWh | $0.06 |
Electricity Demand | $632,049 | 38,720 | kW-months/year | $16.32 |
Electricity Fees | $122,441 | - | $ | - |
Natural Gas | $34,233 | 3,812 | MMBtu | $8.98 |
TOTAL ENERGY COSTS | $2,108,428 | |||
RECOMMENDED SAVINGS* | $564,233 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $103,009 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3137 USE POWER DURING OFF-PEAK PERIODS |
Savings: $65,901 Cost: $200,000 |
$38,961 | - | $26,940 | - | - | - | - | - |
$38,961 - kWh |
$26,940 - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $408 Cost: $586 |
$285 | 4,136 | $123 | 8 | - | - | - | - |
$285 4,136 kWh |
$123 8 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $13,210 Cost: $90,000 |
$12,153 | 176,166 | $1,057 | 259 | - | - | - | - |
$12,153 176,166 kWh |
$1,057 259 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.446 AUTOMATE FINISHING PROCESS |
Savings: $240,621 Cost: $225,000 |
$621 | 9,000 | - | - | $240,000 | - | - | - |
$621 9,000 kWh |
- - kW-months/year |
$240,000 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.514 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS |
Savings: $220,603 Cost: $170,000 |
$3,003 | 15,300 | - | - | $160,000 | - | $57,600 | - |
$3,003 15,300 kWh |
- - kW-months/year |
$160,000 - $ |
$57,600 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY |
Savings: $14,573 Cost: $120,000 |
$10,190 | 147,708 | $4,383 | 269 | - | - | - | - |
$10,190 147,708 kWh |
$4,383 269 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $8,917 Cost: $7,000 |
$3,370 | - | $5,547 | - | - | - | - | - |
$3,370 - kWh |
$5,547 - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $564,233 Cost: $812,586 |
$68,583 | 352,310 | $38,050 | 536 | $400,000 | - | $57,600 | - | $68,583 352,310 kWh |
$38,050 536 kW-months/year |
$400,000 - $ |
$57,600 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $103,009 Cost: $417,586 |
$64,959 | 328,010 | $38,050 | 536 | - | - | - | - | $64,959 328,010 kWh |
$38,050 536 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes |