Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Loyola Marymount University |
---|---|
Assessment Year | 2006 |
Principal Product | mozzarella |
NAICS | 311513 - Cheese Manufacturing |
SIC | 2022 - Cheese, Natural And Processed |
Sales | $100,000,000-$500,000,000 |
# of Employees | 415 |
Plant Area (Sq.Ft.) | 457,000 |
Annual Production | 360,000,000 Pounds |
Production Hrs. Annual | 8,376 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $2,407,024 | 104,597,535 | kWh | $0.02 |
Electricity Demand | $2,407,023 | 243,429 | kW-months/year | $9.89 |
Electricity Fees | $749 | - | $ | - |
TOTAL ENERGY COSTS | $4,814,796 | |||
RECOMMENDED SAVINGS* | $695,704 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $342,345 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Electricity Usage | Electricity Demand | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $12,946 Cost: - |
$7,289 | - | $5,657 | - | - | - |
$7,289 - kWh |
$5,657 - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $111,472 Cost: $82,700 |
$91,870 | 1,039,800 | $19,602 | 1,986 | - | - |
$91,870 1,039,800 kWh |
$19,602 1,986 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $2,913 Cost: $7,000 |
$1,687 | - | $1,226 | - | - | - |
$1,687 - kWh |
$1,226 - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $230,613 Cost: $69,350 |
$192,501 | 2,206,318 | $38,112 | 2,702 | - | - |
$192,501 2,206,318 kWh |
$38,112 2,702 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.451 ADD ADDITIONAL PRODUCTION SHIFT |
Savings: $337,500 Cost: $5,000 |
- | - | - | - | $337,500 | - |
- - kWh |
- - kW-months/year |
$337,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $260 Cost: - |
$260 | 2,945 | - | - | - | - |
$260 2,945 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $695,704 Cost: $164,050 |
$293,607 | 3,249,063 | $64,597 | 4,688 | $337,500 | - | $293,607 3,249,063 kWh |
$64,597 4,688 kW-months/year |
$337,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $342,345 Cost: $152,050 |
$284,631 | 3,249,063 | $57,714 | 4,688 | - | - | $284,631 3,249,063 kWh |
$57,714 4,688 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Electricity Usage | Electricity Demand | Personnel Changes |