Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 2007 |
Principal Product | Watch & Electronic Batteries, Hearing Aid Batteries |
NAICS | 335912 - Primary Battery Manufacturing |
SIC | 3692 - Primary Batteries, Dry And Wet |
Sales | $50,000,000-$100,000,000 |
# of Employees | 209 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 225,000 Pieces |
Production Hrs. Annual | 6,240 |
Location (State) | VT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $657,447 | 10,865,141 | kWh | $0.06 |
Electricity Demand | $320,789 | 20,372 | kW-months/year | $15.75 |
Fuel Oil #4 | $512,848 | 41,099 | MMBtu | $12.48 |
TOTAL ENERGY COSTS | $1,491,084 | |||
RECOMMENDED SAVINGS* | $193,543 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $138,761 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #4 | Electricity Usage | Electricity Demand | Fuel Oil #4 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $62,300 Cost: $24,500 |
- | - | - | - | $62,300 | 4,992 |
- - kWh |
- - kW-months/year |
$62,300 4,992 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $47,607 Cost: $22,000 |
$13,550 | 223,600 | - | - | $34,057 | 2,729 |
$13,550 223,600 kWh |
- - kW-months/year |
$34,057 2,729 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $24,012 Cost: $50,000 |
- | - | - | - | $24,012 | 1,924 |
- - kWh |
- - kW-months/year |
$24,012 1,924 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2625 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE |
Savings: $14,298 Cost: $11,500 |
$1,120 | 18,479 | - | - | $13,178 | 1,056 |
$1,120 18,479 kWh |
- - kW-months/year |
$13,178 1,056 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1116 IMPROVE COMBUSTION CONTROL CAPABILITY |
Savings: $12,255 Cost: $75,000 |
- | - | - | - | $12,255 | 982 |
- - kWh |
- - kW-months/year |
$12,255 982 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $11,448 Cost: $2,500 |
- | - | $11,448 | 1,812 | - | - |
- - kWh |
$11,448 1,812 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $4,741 Cost: - |
$3,233 | 53,352 | $1,508 | 103 | - | - |
$3,233 53,352 kWh |
$1,508 103 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $4,655 Cost: $4,000 |
- | - | - | - | $4,655 | 373 |
- - kWh |
- - kW-months/year |
$4,655 373 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $4,605 Cost: $1,000 |
$4,605 | 76,000 | - | - | - | - |
$4,605 76,000 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $4,007 Cost: $12,000 |
$4,007 | 66,120 | - | - | - | - |
$4,007 66,120 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $2,570 Cost: $15,700 |
$1,750 | 28,872 | $820 | 56 | - | - |
$1,750 28,872 kWh |
$820 56 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,045 Cost: $5,670 |
$430 | 7,151 | $615 | 42 | - | - |
$430 7,151 kWh |
$615 42 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $193,543 Cost: $223,870 |
$28,695 | 473,574 | $14,391 | 2,013 | $150,457 | 12,056 | $28,695 473,574 kWh |
$14,391 2,013 kW-months/year |
$150,457 12,056 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $138,761 Cost: $185,170 |
$8,790 | 145,102 | $13,571 | 1,957 | $116,400 | 9,327 | $8,790 145,102 kWh |
$13,571 1,957 kW-months/year |
$116,400 9,327 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #4 | Electricity Usage | Electricity Demand | Fuel Oil #4 |