Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Missouri, Rolla
Assessment Year 1995
Principal Product Pants
NAICS n/a
SIC 2325 - Men's and Boys' Separate Trousers and Slacks
Sales $5,000,000-$10,000,000
# of Employees 290
Plant Area (Sq.Ft.) 40,000
Annual Production 500,000 Pieces
Production Hrs. Annual 1,960
Location (State) MO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $50,054 989,449 kWh $0.05
LPG $13,422 1,612 MMBtu $8.33
TOTAL ENERGY COSTS $63,476
RECOMMENDED SAVINGS* $12,880 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $6,921
#|Description Savings
Cost
Status Electricity Usage Natural Gas LPG Electricity Usage Natural Gas LPG
$ kWh $ MMBtu $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,303
Cost:
$37,944
$5,303 77,374 - - - - $5,303
77,374
kWh
-
-
MMBtu
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,214
Cost:
$1,488
$2,214 32,239 - - - - $2,214
32,239
kWh
-
-
MMBtu
-
-
MMBtu
03: 2.1332 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS Savings:
$3,337
Cost:
$200
- - $(-9,369) (-1,612) $12,706 1,612 -
-
kWh
$(-9,369)
(-1,612)
MMBtu
$12,706
1,612
MMBtu
04: 2.6121 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED Savings:
$408
Cost:
$150
- - - - $408 49 -
-
kWh
-
-
MMBtu
$408
49
MMBtu
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$521
Cost:
$4,594
$521 7,620 - - - - $521
7,620
kWh
-
-
MMBtu
-
-
MMBtu
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$269
Cost:
$925
$269 3,810 - - - - $269
3,810
kWh
-
-
MMBtu
-
-
MMBtu
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$248
Cost:
$25
$248 4,103 - - - - $248
4,103
kWh
-
-
MMBtu
-
-
MMBtu
08: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$284
Cost:
$171
$284 4,689 - - - - $284
4,689
kWh
-
-
MMBtu
-
-
MMBtu
09: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$296
Cost:
$686
$296 4,396 - - - - $296
4,396
kWh
-
-
MMBtu
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$12,880
Cost:
$46,183
$9,135 134,231 $(-9,369) (-1,612) $13,114 1,661 $9,135
134,231
kWh
$(-9,369)
(-1,612)
MMBtu
$13,114
1,661
MMBtu
TOTAL IMPLEMENTED Savings:
$6,921
Cost:
$8,064
$3,584 52,754 $(-9,369) (-1,612) $12,706 1,612 $3,584
52,754
kWh
$(-9,369)
(-1,612)
MMBtu
$12,706
1,612
MMBtu
Savings
Cost
$ kWh $ MMBtu $ MMBtu
Electricity Usage Natural Gas LPG Electricity Usage Natural Gas LPG