Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 2002 |
Principal Product | Industrial lifting equipment |
NAICS | n/a |
SIC | 3537 - Industrial Trucks And Tractors |
Sales | $50,000,000-$100,000,000 |
# of Employees | 513 |
Plant Area (Sq.Ft.) | 474,000 |
Annual Production | 450 Pieces |
Production Hrs. Annual | 7,000 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $247,968 | 7,166,700 | kWh | $0.03 |
Electricity Demand | $194,314 | 18,297 | kW-months/year | $10.62 |
Electricity Fees | $6,719 | - | $ | - |
Natural Gas | $189,608 | 38,024 | MMBtu | $4.99 |
TOTAL ENERGY COSTS | $696,221 | |||
RECOMMENDED SAVINGS* | $92,238 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $41,542 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $26,748 Cost: $7,400 |
- | - | - | - | - | - | $26,748 | 5,281 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$26,748 5,281 MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $6,371 Cost: $11,500 |
- | - | $6,276 | 640 | $95 | - | - | - | - | - | - | - | - | - |
- - kWh |
$6,276 640 kW-months/year |
$95 - $ |
- - MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,766 Cost: $288 |
$3,708 | 107,175 | - | - | $58 | - | - | - | - | - | - | - | - | - |
$3,708 107,175 kWh |
- - kW-months/year |
$58 - $ |
- - MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $3,765 Cost: $3,400 |
$3,709 | 107,201 | - | - | $56 | - | - | - | - | - | - | - | - | - |
$3,709 107,201 kWh |
- - kW-months/year |
$56 - $ |
- - MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $2,288 Cost: $270 |
$995 | 28,760 | $1,260 | 119 | $33 | - | - | - | - | - | - | - | - | - |
$995 28,760 kWh |
$1,260 119 kW-months/year |
$33 - $ |
- - MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7122 DISCONNECT BALLASTS |
Savings: $1,230 Cost: $1,395 |
$618 | 17,847 | $595 | 56 | $17 | - | - | - | - | - | - | - | - | - |
$618 17,847 kWh |
$595 56 kW-months/year |
$17 - $ |
- - MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $1,517 Cost: $1,416 |
$1,497 | 43,200 | - | - | $20 | - | - | - | - | - | - | - | - | - |
$1,497 43,200 kWh |
- - kW-months/year |
$20 - $ |
- - MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $582 Cost: - |
$573 | 16,572 | - | - | $9 | - | - | - | - | - | - | - | - | - |
$573 16,572 kWh |
- - kW-months/year |
$9 - $ |
- - MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $557 Cost: $200 |
$209 | 6,038 | $340 | 32 | $8 | - | - | - | - | - | - | - | - | - |
$209 6,038 kWh |
$340 32 kW-months/year |
$8 - $ |
- - MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.1193 CONVERT FROM BATCH OPERATION TO CONTINUOUS PROCESSING |
Savings: $6,462 Cost: $6,610 |
- | - | - | - | - | - | - | - | $5,176 | 10,746 | - | - | $1,286 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$5,176 10,746 lb |
- - $ |
$1,286 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $38,952 Cost: $153,600 |
- | - | - | - | - | - | - | - | - | - | $38,952 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - lb |
$38,952 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $92,238 Cost: $186,079 |
$11,309 | 326,793 | $8,471 | 847 | $296 | - | $26,748 | 5,281 | $5,176 | 10,746 | $38,952 | - | $1,286 | - | $11,309 326,793 kWh |
$8,471 847 kW-months/year |
$296 - $ |
$26,748 5,281 MMBtu |
$5,176 10,746 lb |
$38,952 - $ |
$1,286 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $41,542 Cost: $21,053 |
$6,103 | 176,392 | $8,471 | 847 | $220 | - | $26,748 | 5,281 | - | - | - | - | - | - | $6,103 176,392 kWh |
$8,471 847 kW-months/year |
$220 - $ |
$26,748 5,281 MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Personnel Changes | One-time Revenue or Avoided Cost |