IAC logo
IAC Assessment: NC0052
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: NC0052
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center North Carolina State
Assessment Year 1995
Principal Product Pickled cucumbers and peppers
NAICS n/a
SIC 2035 - Pickles, Sauces, And Salad Dressings
Sales $100,000,000-$500,000,000
# of Employees 350
Plant Area (Sq.Ft.) 100,000
Annual Production 40,000,000 Pieces
Production Hrs. Annual 6,000
Location (State) NC
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $459,755 7,971,864 kWh $0.06
Fuel Oil #2 $159,752 61,016 MMBtu $2.62
TOTAL ENERGY COSTS $711,034
RECOMMENDED SAVINGS* $104,186 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $11,728
#|Description Savings
Cost
Status Electricity Usage Fuel Oil #2 Water Disposal Other Liquid (non-haz) Solid Waste (non-haz) Electricity Usage Fuel Oil #2 Water Disposal Other Liquid (non-haz) Solid Waste (non-haz)
$ kWh $ MMBtu $ Tgal $ gal $ lb
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,358
Cost:
$2,000
$1,358 29,894 - - - - - - - - $1,358
29,894
kWh
-
-
MMBtu
-
-
Tgal
-
-
gal
-
-
lb
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$403
Cost:
$100
$403 7,327 - - - - - - - - $403
7,327
kWh
-
-
MMBtu
-
-
Tgal
-
-
gal
-
-
lb
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,087
Cost:
$120
$1,087 22,860 - - - - - - - - $1,087
22,860
kWh
-
-
MMBtu
-
-
Tgal
-
-
gal
-
-
lb
04: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$6,703
Cost:
$15,000
$6,703 214,537 - - - - - - - - $6,703
214,537
kWh
-
-
MMBtu
-
-
Tgal
-
-
gal
-
-
lb
05: 2.1243 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER Savings:
$784
Cost:
$900
- - $784 299 - - - - - - -
-
kWh
$784
299
MMBtu
-
-
Tgal
-
-
gal
-
-
lb
06: 2.1232 KEEP BOILER TUBES CLEAN Savings:
$8,880
Cost:
-
- - $8,880 3,390 - - - - - - -
-
kWh
$8,880
3,390
MMBtu
-
-
Tgal
-
-
gal
-
-
lb
07: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL Savings:
$1,850
Cost:
-
- - - - - - - - $1,850 185,000 -
-
kWh
-
-
MMBtu
-
-
Tgal
-
-
gal
$1,850
185,000
lb
08: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS Savings:
$71,177
Cost:
$500
- - - - - - $71,177 147,262 - - -
-
kWh
-
-
MMBtu
-
-
Tgal
$71,177
147,262
gal
-
-
lb
09: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION Savings:
$11,944
Cost:
$18,477
- - - - $11,944 26,550,000 - - - - -
-
kWh
-
-
MMBtu
$11,944
26,550,000
Tgal
-
-
gal
-
-
lb
TOTAL RECOMMENDED Savings:
$104,186
Cost:
$37,097
$9,551 274,618 $9,664 3,689 $11,944 26,550,000 $71,177 147,262 $1,850 185,000 $9,551
274,618
kWh
$9,664
3,689
MMBtu
$11,944
26,550,000
Tgal
$71,177
147,262
gal
$1,850
185,000
lb
TOTAL IMPLEMENTED Savings:
$11,728
Cost:
$2,220
$2,848 60,081 $8,880 3,390 - - - - - - $2,848
60,081
kWh
$8,880
3,390
MMBtu
-
-
Tgal
-
-
gal
-
-
lb
Savings
Cost
$ kWh $ MMBtu $ Tgal $ gal $ lb
Electricity Usage Fuel Oil #2 Water Disposal Other Liquid (non-haz) Solid Waste (non-haz) Electricity Usage Fuel Oil #2 Water Disposal Other Liquid (non-haz) Solid Waste (non-haz)