Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 1998 |
Principal Product | fiber optic cable |
NAICS | n/a |
SIC | 3357 - Nonferrous Wiredrawing & Insulating |
Sales | $50,000,000-$100,000,000 |
# of Employees | 215 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 114,854 Thousand Feet |
Production Hrs. Annual | 8,600 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $279,323 | 10,777,550 | kWh | $0.03 |
Electricity Demand | $185,006 | 17,925 | kW-months/year | $10.32 |
Electricity Fees | $14,673 | - | $ | - |
TOTAL ENERGY COSTS | $479,002 | |||
RECOMMENDED SAVINGS* | $149,017 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY |
Savings: $9,465 Cost: $14,500 |
$5,789 | 206,917 | $3,676 | 283 | - | - | - | - | - | - |
$5,789 206,917 kWh |
$3,676 283 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $6,949 Cost: $11,150 |
$6,284 | 224,502 | $5,453 | 420 | $(-4,788) | (-955) | - | - | - | - |
$6,284 224,502 kWh |
$5,453 420 kW-months/year |
$(-4,788) (-955) MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $2,486 Cost: $2,688 |
$1,520 | 54,220 | $966 | 74 | - | - | - | - | - | - |
$1,520 54,220 kWh |
$966 74 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $2,506 Cost: $2,940 |
$1,300 | 46,307 | $1,206 | 93 | - | - | - | - | - | - |
$1,300 46,307 kWh |
$1,206 93 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,455 Cost: $1,600 |
$1,455 | 51,876 | - | - | - | - | - | - | - | - |
$1,455 51,876 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $440 Cost: $1,333 |
$261 | 9,379 | $179 | 14 | - | - | - | - | - | - |
$261 9,379 kWh |
$179 14 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,816 Cost: $13,801 |
$3,557 | 127,198 | $2,259 | 174 | - | - | - | - | - | - |
$3,557 127,198 kWh |
$2,259 174 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $900 Cost: $200 |
- | - | - | - | - | - | $900 | 60,000 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$900 60,000 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.321 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES |
Savings: $119,000 Cost: $500 |
- | - | - | - | - | - | - | - | $119,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$119,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $149,017 Cost: $48,712 |
$20,166 | 720,399 | $13,739 | 1,058 | $(-4,788) | (-955) | $900 | 60,000 | $119,000 | - | $20,166 720,399 kWh |
$13,739 1,058 kW-months/year |
$(-4,788) (-955) MMBtu |
$900 60,000 lb |
$119,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Primary Product |