Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2000 |
Principal Product | Knitted fabric |
NAICS | n/a |
SIC | 2253 - Knit Outerwear Mills |
Sales | $5,000,000-$10,000,000 |
# of Employees | 156 |
Plant Area (Sq.Ft.) | 182,640 |
Annual Production | 7,800,000 Pieces |
Production Hrs. Annual | 7,500 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $161,092 | 5,295,428 | kWh | $0.03 |
Electricity Demand | $89,000 | 10,815 | kW-months/year | $8.23 |
Electricity Fees | $7,419 | - | $ | - |
TOTAL ENERGY COSTS | $257,511 | |||
RECOMMENDED SAVINGS* | $44,621 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $10,665 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Administrative Changes | Increase in Production | Electricity Usage | Electricity Demand | Water Disposal | Administrative Changes | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.121 MAINTAIN CLEAN CONDITIONS BEFORE PAINTING |
Savings: $5,811 Cost: $13,000 |
- | - | - | - | $(-2,080) | (-216,000) | - | - | $7,891 | - |
- - kWh |
- - kW-months/year |
$(-2,080) (-216,000) Tgal |
- - $ |
$7,891 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,627 Cost: - |
$1,164 | 38,394 | $1,463 | 175 | - | - | - | - | - | - |
$1,164 38,394 kWh |
$1,463 175 kW-months/year |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $24,784 Cost: $8,500 |
$17,219 | 566,530 | $7,565 | 906 | - | - | - | - | - | - |
$17,219 566,530 kWh |
$7,565 906 kW-months/year |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,597 Cost: $150 |
$1,110 | 35,463 | $487 | 57 | - | - | - | - | - | - |
$1,110 35,463 kWh |
$487 57 kW-months/year |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $630 Cost: $691 |
$438 | 14,361 | $192 | 23 | - | - | - | - | - | - |
$438 14,361 kWh |
$192 23 kW-months/year |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,299 Cost: $220 |
$902 | 29,601 | $397 | 48 | - | - | - | - | - | - |
$902 29,601 kWh |
$397 48 kW-months/year |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,732 Cost: $849 |
$2,421 | 79,719 | $1,311 | 159 | - | - | - | - | - | - |
$2,421 79,719 kWh |
$1,311 159 kW-months/year |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,141 Cost: $6,000 |
$930 | 30,481 | $511 | 61 | - | - | $2,700 | - | - | - |
$930 30,481 kWh |
$511 61 kW-months/year |
- - Tgal |
$2,700 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $44,621 Cost: $29,410 |
$24,184 | 794,549 | $11,926 | 1,429 | $(-2,080) | (-216,000) | $2,700 | - | $7,891 | - | $24,184 794,549 kWh |
$11,926 1,429 kW-months/year |
$(-2,080) (-216,000) Tgal |
$2,700 - $ |
$7,891 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $10,665 Cost: $13,841 |
$2,712 | 88,218 | $2,142 | 255 | $(-2,080) | (-216,000) | - | - | $7,891 | - | $2,712 88,218 kWh |
$2,142 255 kW-months/year |
$(-2,080) (-216,000) Tgal |
- - $ |
$7,891 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Administrative Changes | Increase in Production | Electricity Usage | Electricity Demand | Water Disposal | Administrative Changes | Increase in Production |