Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2001 |
Principal Product | Socks |
NAICS | n/a |
SIC | 2252 - Hosiery, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 155,000 |
Annual Production | 20,000,000 Pieces |
Production Hrs. Annual | 6,000 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $428,792 | 7,417,930 | kWh | $0.06 |
Electricity Demand | $149,063 | 18,017 | kW-months/year | $8.27 |
Electricity Fees | $11,555 | - | $ | - |
Natural Gas | $230,662 | 38,664 | MMBtu | $5.97 |
TOTAL ENERGY COSTS | $820,072 | |||
RECOMMENDED SAVINGS* | $108,896 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $21,005 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $3,205 Cost: $3,300 |
$3,484 | 52,000 | $1,045 | 255 | $(-1,324) | (-222) | - | - |
$3,484 52,000 kWh |
$1,045 255 kW-months/year |
$(-1,324) (-222) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,659 Cost: $6,560 |
$6,125 | 91,411 | $534 | 130 | - | - | - | - |
$6,125 91,411 kWh |
$534 130 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $6,328 Cost: $5,000 |
$(-469) | (-7,000) | $(-98) | (-24) | $6,895 | 1,155 | - | - |
$(-469) (-7,000) kWh |
$(-98) (-24) kW-months/year |
$6,895 1,155 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $2,283 Cost: $1,180 |
- | - | - | - | $2,283 | 382 | - | - |
- - kWh |
- - kW-months/year |
$2,283 382 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7313 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING |
Savings: $22,804 Cost: $35,000 |
$2,082 | 31,080 | - | - | $20,722 | 3,471 | - | - |
$2,082 31,080 kWh |
- - kW-months/year |
$20,722 3,471 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1133 ADJUST BURNERS FOR EFFICIENT OPERATION |
Savings: $11,002 Cost: $2,200 |
- | - | - | - | $11,002 | 1,878 | - | - |
- - kWh |
- - kW-months/year |
$11,002 1,878 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $3,344 Cost: $2,483 |
$3,075 | 45,890 | $269 | 66 | - | - | - | - |
$3,075 45,890 kWh |
$269 66 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2444 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS |
Savings: $25,814 Cost: $29,000 |
- | - | - | - | $25,814 | 4,324 | - | - |
- - kWh |
- - kW-months/year |
$25,814 4,324 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.3416 USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST |
Savings: $27,457 Cost: $100,000 |
$14,800 | 400,000 | $24,900 | 1,200 | $(-8,243) | (-1,381) | $(-4,000) | - |
$14,800 400,000 kWh |
$24,900 1,200 kW-months/year |
$(-8,243) (-1,381) MMBtu |
$(-4,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $108,896 Cost: $184,723 |
$29,097 | 613,381 | $26,650 | 1,627 | $57,149 | 9,607 | $(-4,000) | - | $29,097 613,381 kWh |
$26,650 1,627 kW-months/year |
$57,149 9,607 MMBtu |
$(-4,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $21,005 Cost: $11,243 |
$9,200 | 137,301 | $803 | 196 | $11,002 | 1,878 | - | - | $9,200 137,301 kWh |
$803 196 kW-months/year |
$11,002 1,878 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes |