Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2002 |
Principal Product | Household textile goods |
NAICS | n/a |
SIC | 2392 - Housefurnishings, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 145 |
Plant Area (Sq.Ft.) | 130,000 |
Annual Production | 1,200,000 Pounds |
Production Hrs. Annual | 2,000 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $76,506 | 1,666,800 | kWh | $0.05 |
Electricity Demand | $36,206 | 7,404 | kW-months/year | $4.89 |
Electricity Fees | $252 | - | $ | - |
Natural Gas | $73,266 | 73,073 | MMBtu | $1.00 |
TOTAL ENERGY COSTS | $186,230 | |||
RECOMMENDED SAVINGS* | $32,701 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $8,096 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3134 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION |
Savings: $22,396 Cost: $5,000 |
- | - | $4,020 | 3,748 | $26,376 | - | - | - | $(-8,000) | - |
- - kWh |
$4,020 3,748 kW-months/year |
$26,376 - $ |
- - MMBtu |
$(-8,000) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $1,099 Cost: $1,354 |
$663 | 13,372 | $436 | 89 | - | - | - | - | - | - |
$663 13,372 kWh |
$436 89 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $893 Cost: $500 |
- | - | - | - | - | - | $893 | 71 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$893 71 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,301 Cost: $2,500 |
$1,058 | 21,340 | $243 | 50 | - | - | - | - | - | - |
$1,058 21,340 kWh |
$243 50 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7131 ADD AREA LIGHTING SWITCHES |
Savings: $1,053 Cost: $3,340 |
$661 | 13,340 | $392 | 80 | - | - | - | - | - | - |
$661 13,340 kWh |
$392 80 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $797 Cost: $1,040 |
$501 | 10,098 | $296 | 61 | - | - | - | - | - | - |
$501 10,098 kWh |
$296 61 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7228 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM |
Savings: $645 Cost: $1,100 |
$296 | 5,973 | $349 | 71 | - | - | - | - | - | - |
$296 5,973 kWh |
$349 71 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $263 Cost: - |
- | - | - | - | - | - | $263 | 26 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$263 26 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.1114 LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE |
Savings: $4,254 Cost: $3,500 |
- | - | - | - | - | - | $4,254 | 424 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$4,254 424 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $32,701 Cost: $18,334 |
$3,179 | 64,123 | $5,736 | 4,099 | $26,376 | - | $5,410 | 521 | $(-8,000) | - | $3,179 64,123 kWh |
$5,736 4,099 kW-months/year |
$26,376 - $ |
$5,410 521 MMBtu |
$(-8,000) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $8,096 Cost: $9,734 |
$1,825 | 36,810 | $1,124 | 230 | - | - | $5,147 | 495 | - | - | $1,825 36,810 kWh |
$1,124 230 kW-months/year |
- - $ |
$5,147 495 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||