Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2006 |
Principal Product | Pharmaceutical preparations |
NAICS | 325412 - Pharmaceutical Preparation Manufacturing |
SIC | 2834 - Pharmaceutical Preparations |
Sales | $10,000,000-$50,000,000 |
# of Employees | 180 |
Plant Area (Sq.Ft.) | 51,200 |
Annual Production | 2,000,000 Pieces |
Production Hrs. Annual | 2,500 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $126,358 | 4,555,800 | kWh | $0.03 |
Electricity Demand | $202,835 | 17,766 | kW-months/year | $11.42 |
Electricity Fees | $11,602 | - | $ | - |
Natural Gas | $267,513 | 20,557 | MMBtu | $13.01 |
TOTAL ENERGY COSTS | $608,308 | |||
RECOMMENDED SAVINGS* | $78,410 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3192 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS |
Savings: $20,455 Cost: $12,000 |
$387 | 14,400 | $22,878 | 1,800 | - | - | $(-2,810) | (-197) |
$387 14,400 kWh |
$22,878 1,800 kW-months/year |
- - MMBtu |
$(-2,810) (-197) MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3113 MAKE ICE DURING OFF PEAK HOURS FOR COOLING |
Savings: $39,950 Cost: $210,000 |
- | - | $39,950 | 3,141 | - | - | - | - |
- - kWh |
$39,950 3,141 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2492 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR |
Savings: $17,210 Cost: $28,200 |
$(-1,277) | (-47,533) | $(-69) | (-4) | $18,556 | 1,426 | - | - |
$(-1,277) (-47,533) kWh |
$(-69) (-4) kW-months/year |
$18,556 1,426 MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2123 INSULATE FEEDWATER TANK |
Savings: $389 Cost: $277 |
- | - | - | - | $389 | 30 | - | - |
- - kWh |
- - kW-months/year |
$389 30 MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $406 Cost: $86 |
$208 | 7,750 | $198 | 12 | - | - | - | - |
$208 7,750 kWh |
$198 12 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $78,410 Cost: $250,563 |
$(-682) | (-25,383) | $62,957 | 4,949 | $18,945 | 1,456 | $(-2,810) | (-197) | $(-682) (-25,383) kWh |
$62,957 4,949 kW-months/year |
$18,945 1,456 MMBtu |
$(-2,810) (-197) MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 |