Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2012 |
Principal Product | Shampoos and deodorants |
NAICS | 325620 - Toilet Preparation Manufacturing |
SIC | 2844 - Toilet Preparations |
Sales | $100,000,000-$500,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 550,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 8,760 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,154,357 | 19,940,560 | kWh | $0.06 |
Electricity Demand | $1,373,289 | 164,269 | kW-months/year | $8.36 |
Natural Gas | $175,479 | 33,922 | MMBtu | $5.17 |
TOTAL ENERGY COSTS | $2,703,125 | |||
RECOMMENDED SAVINGS* | $140,111 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $95,008 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $87,056 Cost: $77,718 |
$73,553 | 1,143,198 | $13,092 | 1,566 | - | - | $411 | - |
$73,553 1,143,198 kWh |
$13,092 1,566 kW-months/year |
- - $ |
$411 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,873 Cost: $35,445 |
$5,453 | 84,751 | $2,420 | 289 | - | - | - | - |
$5,453 84,751 kWh |
$2,420 289 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $79 Cost: $110 |
$10 | 160 | $62 | 7 | - | - | $7 | - |
$10 160 kWh |
$62 7 kW-months/year |
- - $ |
$7 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $42,271 Cost: $58,000 |
$42,271 | 657,000 | - | - | - | - | - | - |
$42,271 657,000 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.5194 REDESIGN PROCESS |
Savings: $2,832 Cost: $1,000 |
$4,822 | 74,952 | $843 | 101 | $(-2,833) | - | - | - |
$4,822 74,952 kWh |
$843 101 kW-months/year |
$(-2,833) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $140,111 Cost: $172,273 |
$126,109 | 1,960,061 | $16,417 | 1,963 | $(-2,833) | - | $418 | - | $126,109 1,960,061 kWh |
$16,417 1,963 kW-months/year |
$(-2,833) - $ |
$418 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $95,008 Cost: $113,273 |
$79,016 | 1,228,109 | $15,574 | 1,862 | - | - | $418 | - | $79,016 1,228,109 kWh |
$15,574 1,862 kW-months/year |
- - $ |
$418 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost |