Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2014 |
Principal Product | Trucks |
NAICS | 333120 - Construction Machinery Manufacturing |
SIC | 3713 - Truck And Bus Bodies |
Sales | >$500,000,000 |
# of Employees | 2,500 |
Plant Area (Sq.Ft.) | 1,300,000 |
Annual Production | 27,000 Pieces |
Production Hrs. Annual | 4,500 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $2,247,975 | 55,545,600 | kWh | $0.04 |
Electricity Demand | $1,210,965 | 135,594 | kW-months/year | $8.93 |
Electricity Fees | $8,533 | - | $ | - |
Natural Gas | $1,448,941 | 247,626 | MMBtu | $5.85 |
TOTAL ENERGY COSTS | $5,354,264 | |||
RECOMMENDED SAVINGS* | $194,623 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $151,295 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $18,930 Cost: $1,250 |
$18,930 | 467,418 | - | - | - | - | - | - | - | - | - | - |
$18,930 467,418 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $74,398 Cost: $162,227 |
$37,066 | 915,210 | $16,347 | 1,830 | - | - | - | - | - | - | $20,985 | - |
$37,066 915,210 kWh |
$16,347 1,830 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
$20,985 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $47,226 Cost: $215,258 |
$32,772 | 809,190 | $14,454 | 1,618 | - | - | - | - | - | - | - | - |
$32,772 809,190 kWh |
$14,454 1,618 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $6,998 Cost: $2,000 |
- | - | - | - | - | - | $6,998 | 449 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$6,998 449 Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $5,506 Cost: $15,200 |
- | - | - | - | $5,506 | 941 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$5,506 941 MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $5,090 Cost: $12,500 |
- | - | - | - | $5,090 | 870 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$5,090 870 MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $3,941 Cost: $5,000 |
- | - | - | - | $3,941 | 674 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,941 674 MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $8,395 Cost: $100 |
$8,158 | 201,420 | $4,797 | 537 | - | - | - | - | $(-3,360) | - | $(-1,200) | - |
$8,158 201,420 kWh |
$4,797 537 kW-months/year |
- - MMBtu |
- - Tgal |
$(-3,360) - $ |
$(-1,200) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4225 INSTALL COMMON HEADER ON COMPRESSORS |
Savings: $9,004 Cost: $8,600 |
$5,672 | 140,045 | $3,332 | 373 | - | - | - | - | - | - | - | - |
$5,672 140,045 kWh |
$3,332 373 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $2,346 Cost: $200 |
$540 | - | $1,806 | 187 | - | - | - | - | - | - | - | - |
$540 - kWh |
$1,806 187 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $10,806 Cost: $5,000 |
$4,469 | 110,250 | $6,337 | 710 | - | - | - | - | - | - | - | - |
$4,469 110,250 kWh |
$6,337 710 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $1,458 Cost: $4,256 |
$918 | 22,666 | $540 | 60 | - | - | - | - | - | - | - | - |
$918 22,666 kWh |
$540 60 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $525 Cost: $160 |
$173 | 4,275 | $53 | 6 | - | - | - | - | - | - | $299 | - |
$173 4,275 kWh |
$53 6 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
$299 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $194,623 Cost: $431,751 |
$108,698 | 2,670,474 | $47,666 | 5,321 | $14,537 | 2,485 | $6,998 | 449 | $(-3,360) | - | $20,084 | - | $108,698 2,670,474 kWh |
$47,666 5,321 kW-months/year |
$14,537 2,485 MMBtu |
$6,998 449 Tgal |
$(-3,360) - $ |
$20,084 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $151,295 Cost: $379,035 |
$97,466 | 2,393,238 | $37,404 | 4,172 | - | - | - | - | $(-3,360) | - | $19,785 | - | $97,466 2,393,238 kWh |
$37,404 4,172 kW-months/year |
- - MMBtu |
- - Tgal |
$(-3,360) - $ |
$19,785 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Ancillary Material Cost |