Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2015 |
Principal Product | Mobile homes |
NAICS | 321991 - Manufactured Home (Mobile Home) Manufacturing |
SIC | 2451 - Mobile Homes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 192 |
Plant Area (Sq.Ft.) | 240,000 |
Annual Production | 1,264 Pieces |
Production Hrs. Annual | 2,125 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $167,760 | 2,796,000 | kWh | $0.06 |
Electricity Demand | $30,991 | 6,708 | kW-months/year | $4.62 |
Electricity Fees | $5,802 | - | $ | - |
LPG | $33,137 | 1,511 | MMBtu | $21.93 |
TOTAL ENERGY COSTS | $237,690 | |||
RECOMMENDED SAVINGS* | $32,450 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $3,768 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | LPG | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | LPG | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7228 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM |
Savings: $2,606 Cost: $2,200 |
- | - | - | - | - | - | $2,606 | 119 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$2,606 119 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $6,491 Cost: $20,000 |
- | - | - | - | - | - | $6,491 | 296 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$6,491 296 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1332 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS |
Savings: $20,292 Cost: $100,000 |
- | - | - | - | $(-12,845) | (-1,511) | $33,137 | 1,511 | - | - | - | - |
- - kWh |
- - kW-months/year |
$(-12,845) (-1,511) MMBtu |
$33,137 1,511 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $349 Cost: $96 |
$154 | 2,565 | $16 | 4 | - | - | - | - | - | - | $179 | - |
$154 2,565 kWh |
$16 4 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
$179 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $402 Cost: $1,455 |
$280 | 4,667 | $122 | 26 | - | - | - | - | - | - | - | - |
$280 4,667 kWh |
$122 26 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,202 Cost: $5,000 |
$837 | 13,959 | $365 | 79 | - | - | - | - | - | - | - | - |
$837 13,959 kWh |
$365 79 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $411 Cost: $100 |
$468 | 7,799 | $203 | 44 | - | - | - | - | $(-200) | - | $(-60) | - |
$468 7,799 kWh |
$203 44 kW-months/year |
- - MMBtu |
- - MMBtu |
$(-200) - $ |
$(-60) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $697 Cost: $2,500 |
$486 | 8,096 | $211 | 46 | - | - | - | - | - | - | - | - |
$486 8,096 kWh |
$211 46 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $32,450 Cost: $131,351 |
$2,225 | 37,086 | $917 | 199 | $(-12,845) | (-1,511) | $42,234 | 1,926 | $(-200) | - | $119 | - | $2,225 37,086 kWh |
$917 199 kW-months/year |
$(-12,845) (-1,511) MMBtu |
$42,234 1,926 MMBtu |
$(-200) - $ |
$119 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $3,768 Cost: $3,851 |
$902 | 15,031 | $341 | 74 | - | - | $2,606 | 119 | $(-200) | - | $119 | - | $902 15,031 kWh |
$341 74 kW-months/year |
- - MMBtu |
$2,606 119 MMBtu |
$(-200) - $ |
$119 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | LPG | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | LPG | Personnel Changes | Ancillary Material Cost |