Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2008 |
Principal Product | Aluminium Extrusions |
NAICS | 332321 - Metal Window and Door Manufacturing |
SIC | 3442 - Metal Doors, Sash, And Trim |
Sales | $100,000,000-$500,000,000 |
# of Employees | 655 |
Plant Area (Sq.Ft.) | 430,000 |
Annual Production | 25,000,000 Pounds |
Production Hrs. Annual | 7,488 |
Location (State) | AR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,137,765 | 24,002,112 | kWh | $0.05 |
Natural Gas | $1,083,147 | 113,427 | MMBtu | $9.55 |
TOTAL ENERGY COSTS | $2,220,912 | |||
RECOMMENDED SAVINGS* | $389,605 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $177,910 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Water Consumption | Electricity Usage | Natural Gas | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $959 Cost: $398 |
$959 | 73 | - | - | - | - |
$959 73 kWh |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,022 Cost: $4,452 |
$2,022 | 219 | - | - | - | - |
$2,022 219 kWh |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $10,704 Cost: $17,980 |
$10,704 | 412 | - | - | - | - |
$10,704 412 kWh |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $208 Cost: $1,615 |
$208 | 18 | - | - | - | - |
$208 18 kWh |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $441 Cost: $2,703 |
$441 | 28 | - | - | - | - |
$441 28 kWh |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,145 Cost: $16,980 |
$2,145 | 137 | - | - | - | - |
$2,145 137 kWh |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $463 Cost: $2,027 |
$463 | 35 | - | - | - | - |
$463 35 kWh |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4159 REPLACE TREATED WATER WITH WELL / SURFACE WATER |
Savings: $12,550 Cost: $152,330 |
- | - | - | - | $12,550 | - |
- - kWh |
- - MMBtu |
$12,550 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $11,400 Cost: $7,484 |
- | - | $11,400 | 1,067 | - | - |
- - kWh |
$11,400 1,067 MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,626 Cost: $749 |
$1,626 | 121 | - | - | - | - |
$1,626 121 kWh |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $16,897 Cost: $1,517 |
$16,897 | 1,860 | - | - | - | - |
$16,897 1,860 kWh |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $7,034 Cost: $129,640 |
$7,034 | 545 | - | - | - | - |
$7,034 545 kWh |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION |
Savings: $25,952 Cost: $64,800 |
$25,952 | 1,993 | - | - | - | - |
$25,952 1,993 kWh |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $2,760 Cost: $7,525 |
$2,760 | 236 | - | - | - | - |
$2,760 236 kWh |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 2.1116 IMPROVE COMBUSTION CONTROL CAPABILITY |
Savings: $131,460 Cost: $41,080 |
- | - | $131,460 | 14,478 | - | - |
- - kWh |
$131,460 14,478 MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
16: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $23,790 Cost: $36,060 |
- | - | $23,790 | 2,620 | - | - |
- - kWh |
$23,790 2,620 MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
17: 3.4113 TREAT AND REUSE RINSE WATERS |
Savings: $139,194 Cost: $135,000 |
- | - | - | - | $139,194 | - |
- - kWh |
- - MMBtu |
$139,194 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $389,605 Cost: $622,340 |
$71,211 | 5,677 | $166,650 | 18,165 | $151,744 | - | $71,211 5,677 kWh |
$166,650 18,165 MMBtu |
$151,744 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $177,910 Cost: $261,025 |
$46,450 | 3,186 | $131,460 | 14,478 | - | - | $46,450 3,186 kWh |
$131,460 14,478 MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Water Consumption | Electricity Usage | Natural Gas | Water Consumption |