Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 1989 |
Principal Product | COMPOSITE PANELS |
NAICS | n/a |
SIC | 2493 - Reconstituted Wood Products |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 797,739 Pieces |
Production Hrs. Annual | 8,736 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $320,137 | 7,822,685 | kWh | $0.04 |
Natural Gas | $281,445 | 68,461 | MMBtu | $4.11 |
Wood | $59,442 | 53,380 | MMBtu | $1.11 |
TOTAL ENERGY COSTS | $661,024 | |||
RECOMMENDED SAVINGS* | $11,556 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,906 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Wood | Administrative Changes | Electricity Usage | Natural Gas | Wood | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2122 INSTALL / REPAIR INSULATION ON CONDENSATE LINES |
Savings: $1,178 Cost: $418 |
- | - | $1,042 | 253 | $136 | 123 | - | - |
- - kWh |
$1,042 253 MMBtu |
$136 123 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,507 Cost: $768 |
$1,507 | 36,635 | - | - | - | - | - | - |
$1,507 36,635 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2122 INSTALL / REPAIR INSULATION ON CONDENSATE LINES |
Savings: $500 Cost: $255 |
- | - | $443 | 108 | $57 | 52 | - | - |
- - kWh |
$443 108 MMBtu |
$57 52 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,561 Cost: $1,210 |
$814 | 19,930 | - | - | - | - | $747 | - |
$814 19,930 kWh |
- - MMBtu |
- - MMBtu |
$747 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $518 Cost: $467 |
$809 | 19,637 | - | - | - | - | $(-291) | - |
$809 19,637 kWh |
- - MMBtu |
- - MMBtu |
$(-291) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $227 Cost: $300 |
$227 | 5,569 | - | - | - | - | - | - |
$227 5,569 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $642 Cost: $1,144 |
$1,417 | 34,584 | - | - | - | - | $(-775) | - |
$1,417 34,584 kWh |
- - MMBtu |
- - MMBtu |
$(-775) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $5,423 Cost: $11,400 |
$5,423 | - | - | - | - | - | - | - |
$5,423 - kWh |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $11,556 Cost: $15,962 |
$10,197 | 116,355 | $1,485 | 361 | $193 | 175 | $(-319) | - | $10,197 116,355 kWh |
$1,485 361 MMBtu |
$193 175 MMBtu |
$(-319) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,906 Cost: $4,262 |
$4,547 | 110,786 | $1,485 | 361 | $193 | 175 | $(-319) | - | $4,547 110,786 kWh |
$1,485 361 MMBtu |
$193 175 MMBtu |
$(-319) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Wood | Administrative Changes | Electricity Usage | Natural Gas | Wood | Administrative Changes |