Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 1996 |
Principal Product | maraschino cherries |
NAICS | n/a |
SIC | 2033 - Canned Fruits And Vegetables |
Sales | $50,000,000-$100,000,000 |
# of Employees | 102 |
Plant Area (Sq.Ft.) | 120,000 |
Annual Production | 16,117,786 Pounds |
Production Hrs. Annual | 6,000 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $93,032 | 2,446,366 | kWh | $0.04 |
Electricity Demand | $27,459 | 6,864 | kW-months/year | $4.00 |
Electricity Fees | $4,860 | - | $ | - |
Natural Gas | $186,884 | 71,633 | MMBtu | $2.61 |
TOTAL ENERGY COSTS | $798,112 | |||
RECOMMENDED SAVINGS* | $79,689 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $7,221 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | lb | $ | $ | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2163 USE MINIMUM STEAM OPERATING PRESSURE |
Savings: $1,474 Cost: - |
- | - | - | - | - | - | $1,474 | 503 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$1,474 503 MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2122 INSTALL / REPAIR INSULATION ON CONDENSATE LINES |
Savings: $715 Cost: $1,566 |
- | - | - | - | - | - | $715 | 244 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$715 244 MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7145 INSTALL SKYLIGHTS |
Savings: $1,025 Cost: $2,800 |
$399 | 10,844 | $311 | 65 | - | - | - | - | - | - | - | - | $179 | - | $136 | - | - | - |
$399 10,844 kWh |
$311 65 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - lb |
$179 - $ |
$136 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $1,521 Cost: $5,500 |
- | - | - | - | $1,521 | - | - | - | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,521 - $ |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $5,430 Cost: $10,982 |
$3,915 | 106,096 | $1,515 | 316 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$3,915 106,096 kWh |
$1,515 316 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,593 Cost: $4,500 |
$1,270 | 34,291 | $323 | 67 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$1,270 34,291 kWh |
$323 67 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $5,032 Cost: $29,713 |
$4,093 | 110,785 | $939 | 196 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$4,093 110,785 kWh |
$939 196 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $6,893 Cost: $10,803 |
$5,672 | 153,576 | $1,221 | 254 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$5,672 153,576 kWh |
$1,221 254 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.7211 MODIFY MATERIAL APPLICATION METHODS |
Savings: $6,750 Cost: $350 |
- | - | - | - | - | - | - | - | - | - | $6,750 | 7,500 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
$6,750 7,500 lb |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.7121 IMPROVE HANDLING PRACTICES |
Savings: $44,620 Cost: $47,924 |
- | - | - | - | - | - | - | - | - | - | - | - | $44,620 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - lb |
$44,620 - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.4151 MINIMIZE WATER USAGE |
Savings: $4,636 Cost: $14,416 |
- | - | - | - | - | - | - | - | $3,591 | 1,526,000 | - | - | - | - | - | - | $1,045 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$3,591 1,526,000 Tgal |
- - lb |
- - $ |
- - $ |
$1,045 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $79,689 Cost: $128,554 |
$15,349 | 415,592 | $4,309 | 898 | $1,521 | - | $2,189 | 747 | $3,591 | 1,526,000 | $6,750 | 7,500 | $44,799 | - | $136 | - | $1,045 | - | $15,349 415,592 kWh |
$4,309 898 kW-months/year |
$1,521 - $ |
$2,189 747 MMBtu |
$3,591 1,526,000 Tgal |
$6,750 7,500 lb |
$44,799 - $ |
$136 - $ |
$1,045 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $7,221 Cost: $31,279 |
$4,093 | 110,785 | $939 | 196 | - | - | $2,189 | 747 | - | - | - | - | - | - | - | - | - | - | $4,093 110,785 kWh |
$939 196 kW-months/year |
- - $ |
$2,189 747 MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | lb | $ | $ | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | Water Consumption |