Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2007 |
Principal Product | plywood |
NAICS | 321212 - Softwood Veneer and Plywood Manufacturing |
SIC | 2493 - Reconstituted Wood Products |
Sales | $50,000,000-$100,000,000 |
# of Employees | 305 |
Plant Area (Sq.Ft.) | 700,000 |
Annual Production | 250,000 Thousand Feet |
Production Hrs. Annual | 7,300 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $918,488 | 25,923,000 | kWh | $0.04 |
Electricity Demand | $212,010 | 55,500 | kW-months/year | $3.82 |
Electricity Fees | $39,915 | - | $ | - |
TOTAL ENERGY COSTS | $1,185,525 | |||
RECOMMENDED SAVINGS* | $220,870 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $220,870 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Wood | Electricity Usage | Electricity Demand | Wood | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2127 FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM |
Savings: $92,300 Cost: $44,300 |
- | - | - | - | $92,300 | 69,900 |
- - kWh |
- - kW-months/year |
$92,300 69,900 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY |
Savings: $37,000 Cost: $20,600 |
$37,000 | 157,200 | - | - | - | - |
$37,000 157,200 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $27,300 Cost: - |
$27,300 | 658,400 | - | - | - | - |
$27,300 658,400 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $27,800 Cost: $12,500 |
$27,800 | 78,840 | - | - | - | - |
$27,800 78,840 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $9,600 Cost: $9,600 |
$9,600 | 225,200 | - | - | - | - |
$9,600 225,200 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $7,300 Cost: - |
$7,300 | 170,500 | - | - | - | - |
$7,300 170,500 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $7,100 Cost: $45,000 |
$6,185 | 176,700 | $915 | 20 | - | - |
$6,185 176,700 kWh |
$915 20 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,250 Cost: $9,300 |
$4,800 | 136,900 | $450 | 10 | - | - |
$4,800 136,900 kWh |
$450 10 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,720 Cost: $5,100 |
$3,600 | 102,044 | $120 | 3 | - | - |
$3,600 102,044 kWh |
$120 3 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $1,600 Cost: $4,500 |
$1,600 | 45,900 | - | - | - | - |
$1,600 45,900 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $1,900 Cost: $1,800 |
$1,900 | 38,000 | - | - | - | - |
$1,900 38,000 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $220,870 Cost: $152,700 |
$127,085 | 1,789,684 | $1,485 | 33 | $92,300 | 69,900 | $127,085 1,789,684 kWh |
$1,485 33 kW-months/year |
$92,300 69,900 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $220,870 Cost: $152,700 |
$127,085 | 1,789,684 | $1,485 | 33 | $92,300 | 69,900 | $127,085 1,789,684 kWh |
$1,485 33 kW-months/year |
$92,300 69,900 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Wood | Electricity Usage | Electricity Demand | Wood |