Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2018 |
Principal Product | veneer/hydromulch |
NAICS | 321211 - Hardwood Veneer and Plywood Manufacturing |
SIC | 2435 - Hardwood Veneer And Plywood |
Sales | $10,000,000-$50,000,000 |
# of Employees | 65 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 600,000 Units |
Production Hrs. Annual | 5,200 |
Location (State) | WA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $359,763 | 8,373,600 | kWh | $0.04 |
Electricity Demand | $186,739 | 23,608 | kW-months/year | $7.91 |
Electricity Fees | $630 | - | $ | - |
Natural Gas | $108,991 | 33,932 | MMBtu | $3.21 |
Wood | $190,789 | 27,720 | MMBtu | $6.88 |
TOTAL ENERGY COSTS | $846,912 | |||
RECOMMENDED SAVINGS* | $67,227 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Primary Raw Material | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.444 INSTALL SYSTEM TO COLLECT SCRAP |
Savings: $35,903 Cost: $29,900 |
- | - | - | - | $35,903 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$35,903 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2128 USE STEAM CONDENSATE FOR HOT WATER SUPPLY (NON-POTABLE) |
Savings: $17,929 Cost: $8,549 |
- | - | - | - | - | - | $17,929 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$17,929 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY |
Savings: $11,954 Cost: $11,773 |
$10,174 | 211,958 | $1,780 | 225 | - | - | - | - | - | - |
$10,174 211,958 kWh |
$1,780 225 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,441 Cost: $4,175 |
$1,010 | 21,045 | $234 | 30 | $238 | - | - | - | $(-41) | - |
$1,010 21,045 kWh |
$234 30 kW-months/year |
$238 - $ |
- - $ |
$(-41) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $67,227 Cost: $54,397 |
$11,184 | 233,003 | $2,014 | 255 | $36,141 | - | $17,929 | - | $(-41) | - | $11,184 233,003 kWh |
$2,014 255 kW-months/year |
$36,141 - $ |
$17,929 - $ |
$(-41) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||