Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 1996 |
Principal Product | Automotive Batteries |
NAICS | n/a |
SIC | 3691 - Storage Batteries |
Sales | $50,000,000-$100,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 254,000 |
Annual Production | 2,200,000 Pieces |
Production Hrs. Annual | 6,125 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,604,769 | 26,303,928 | kWh | $0.06 |
Electricity Demand | $383,479 | 60,471 | kW-months/year | $6.34 |
Electricity Fees | $1,988,248 | - | $ | - |
Natural Gas | $113,358 | 50,400 | MMBtu | $2.25 |
TOTAL ENERGY COSTS | $4,097,399 | |||
RECOMMENDED SAVINGS* | $52,544 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $52,544 |
#|Description |
Savings Cost |
Status | Electricity Usage | Other Liquid (haz) | Personnel Changes | Electricity Usage | Other Liquid (haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | gal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $5,249 Cost: $3,880 |
$5,249 | 73,271 | - | - | - | - |
$5,249 73,271 kWh |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7145 INSTALL SKYLIGHTS |
Savings: $4,543 Cost: $14,692 |
$4,543 | 41,325 | - | - | - | - |
$4,543 41,325 kWh |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,155 Cost: $8,557 |
$5,155 | 71,805 | - | - | - | - |
$5,155 71,805 kWh |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $11,009 Cost: $11,610 |
$11,009 | 150,059 | - | - | - | - |
$11,009 150,059 kWh |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,443 Cost: $665 |
$3,443 | 47,479 | - | - | - | - |
$3,443 47,479 kWh |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.7211 MODIFY MATERIAL APPLICATION METHODS |
Savings: $1,920 Cost: $350 |
- | - | $1,920 | 480 | - | - |
- - kWh |
$1,920 480 gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.8143 RECYCLE CLEANING SOLVENT AND REUSE |
Savings: $5,625 Cost: $50 |
- | - | $5,625 | 43,270 | - | - |
- - kWh |
$5,625 43,270 gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $15,600 Cost: - |
- | - | - | - | $15,600 | - |
- - kWh |
- - gal |
$15,600 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $52,544 Cost: $39,804 |
$29,399 | 383,939 | $7,545 | 43,750 | $15,600 | - | $29,399 383,939 kWh |
$7,545 43,750 gal |
$15,600 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $52,544 Cost: $39,804 |
$29,399 | 383,939 | $7,545 | 43,750 | $15,600 | - | $29,399 383,939 kWh |
$7,545 43,750 gal |
$15,600 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | gal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Other Liquid (haz) | Personnel Changes | Electricity Usage | Other Liquid (haz) | Personnel Changes |