Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 1997 |
Principal Product | Bath Tubs |
NAICS | n/a |
SIC | 3083 - Laminated Plastics Plate & Sheet |
Sales | $50,000,000-$100,000,000 |
# of Employees | 350 |
Plant Area (Sq.Ft.) | 125,000 |
Annual Production | 125,000 Pieces |
Production Hrs. Annual | 4,250 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $288,542 | 4,046,600 | kWh | $0.07 |
Electricity Demand | $149,810 | 16,265 | kW-months/year | $9.21 |
TOTAL ENERGY COSTS | $438,352 | |||
RECOMMENDED SAVINGS* | $450,256 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $450,256 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $3,217 Cost: $3,300 |
$2,390 | 33,705 | $827 | 90 | - | - | - | - | - | - |
$2,390 33,705 kWh |
$827 90 kW-months/year |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,369 Cost: - |
$1,001 | 14,068 | $368 | 40 | - | - | - | - | - | - |
$1,001 14,068 kWh |
$368 40 kW-months/year |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,422 Cost: $650 |
$3,237 | 45,721 | $1,185 | 129 | - | - | - | - | - | - |
$3,237 45,721 kWh |
$1,185 129 kW-months/year |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $24,199 Cost: $1,500 |
$13,147 | 185,229 | $11,052 | 1,200 | - | - | - | - | - | - |
$13,147 185,229 kWh |
$11,052 1,200 kW-months/year |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $2,716 Cost: $900 |
$2,716 | 38,394 | - | - | - | - | - | - | - | - |
$2,716 38,394 kWh |
- - kW-months/year |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,237 Cost: $2,754 |
$1,237 | 11,723 | - | - | - | - | - | - | - | - |
$1,237 11,723 kWh |
- - kW-months/year |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $3,369 Cost: $4,110 |
$3,369 | 32,532 | - | - | - | - | - | - | - | - |
$3,369 32,532 kWh |
- - kW-months/year |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,812 Cost: $1,476 |
$3,812 | 37,808 | - | - | - | - | - | - | - | - |
$3,812 37,808 kWh |
- - kW-months/year |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.122 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS |
Savings: $50,000 Cost: - |
- | - | - | - | - | - | $50,000 | 12,500 | - | - |
- - kWh |
- - kW-months/year |
- - gal |
$50,000 12,500 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.8224 CONVERT TO LESS TOXIC HYDROCARBON CLEANERS |
Savings: $12,265 Cost: - |
- | - | - | - | $12,265 | 2,500 | - | - | - | - |
- - kWh |
- - kW-months/year |
$12,265 2,500 gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.7198 REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT |
Savings: $2,250 Cost: $1,100 |
- | - | - | - | - | - | - | - | $2,250 | - |
- - kWh |
- - kW-months/year |
- - gal |
- - lb |
$2,250 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $45,000 Cost: $3,500 |
- | - | - | - | - | - | $45,000 | 90,000 | - | - |
- - kWh |
- - kW-months/year |
- - gal |
$45,000 90,000 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $296,400 Cost: $20,000 |
- | - | - | - | - | - | - | - | $296,400 | - |
- - kWh |
- - kW-months/year |
- - gal |
- - lb |
$296,400 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $450,256 Cost: $39,290 |
$30,909 | 399,180 | $13,432 | 1,459 | $12,265 | 2,500 | $95,000 | 102,500 | $298,650 | - | $30,909 399,180 kWh |
$13,432 1,459 kW-months/year |
$12,265 2,500 gal |
$95,000 102,500 lb |
$298,650 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $450,256 Cost: $39,290 |
$30,909 | 399,180 | $13,432 | 1,459 | $12,265 | 2,500 | $95,000 | 102,500 | $298,650 | - | $30,909 399,180 kWh |
$13,432 1,459 kW-months/year |
$12,265 2,500 gal |
$95,000 102,500 lb |
$298,650 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (non-haz) | Administrative Changes |