IAC logo
IAC Assessment: SD0484
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SD0484
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 2014
Principal Product Electronic Housing and Heat Control Devices
NAICS 332999 - All Other Miscellaneous Fabricated Metal Product Manufacturing
SIC 3499 - Fabricated Metal Products, Nec
Sales $10,000,000-$50,000,000
# of Employees 95
Plant Area (Sq.Ft.) 19,000
Annual Production 10,000 Pieces
Production Hrs. Annual 6,000
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $273,057 3,388,606 kWh $0.08
Electricity Demand $224,760 8,449 kW-months/year $26.60
Electricity Fees $32,434 - $ -
Natural Gas $11,407 1,534 MMBtu $7.44
TOTAL ENERGY COSTS $541,658
RECOMMENDED SAVINGS* $151,606 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $38,267
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$111,951
Cost:
$87,500
$66,706 827,621 $71,501 2,688 $(-26,256) (-3,529) $66,706
827,621
kWh
$71,501
2,688
kW-months/year
$(-26,256)
(-3,529)
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$20,136
Cost:
$45,100
$12,129 150,504 $8,007 301 - - $12,129
150,504
kWh
$8,007
301
kW-months/year
-
-
MMBtu
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$7,196
Cost:
$1,300
$5,278 65,492 $1,918 72 - - $5,278
65,492
kWh
$1,918
72
kW-months/year
-
-
MMBtu
04: 2.6241 REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY Savings:
$6,896
Cost:
$400
$6,896 85,554 - - - - $6,896
85,554
kWh
-
-
kW-months/year
-
-
MMBtu
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,758
Cost:
$300
$2,758 34,219 - - - - $2,758
34,219
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,388
Cost:
$4,600
$738 9,157 $650 24 - - $738
9,157
kWh
$650
24
kW-months/year
-
-
MMBtu
07: 2.7134 USE PHOTOCELL CONTROLS Savings:
$1,281
Cost:
$3,700
$1,100 13,646 $181 7 - - $1,100
13,646
kWh
$181
7
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$151,606
Cost:
$142,900
$95,605 1,186,193 $82,257 3,092 $(-26,256) (-3,529) $95,605
1,186,193
kWh
$82,257
3,092
kW-months/year
$(-26,256)
(-3,529)
MMBtu
TOTAL IMPLEMENTED Savings:
$38,267
Cost:
$50,800
$28,161 349,415 $10,106 380 - - $28,161
349,415
kWh
$10,106
380
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas