Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 2014 |
Principal Product | treated sewage water |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | <$500,000 |
# of Employees | 6 |
Plant Area (Sq.Ft.) | 600,000 |
Annual Production | 730,000 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $132,386 | 1,953,995 | kWh | $0.07 |
Electricity Demand | $53,047 | 4,355 | kW-months/year | $12.18 |
Electricity Fees | $3,626 | - | $ | - |
TOTAL ENERGY COSTS | $189,059 | |||
RECOMMENDED SAVINGS* | $88,765 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $33,419 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $55,346 Cost: $151,250 |
$76,171 | 1,123,470 | $16,443 | 1,350 | $(-37,268) | (-10,648) |
$76,171 1,123,470 kWh |
$16,443 1,350 kW-months/year |
$(-37,268) (-10,648) MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $13,532 Cost: $99,966 |
$1,536 | - | $11,996 | 1,150 | - | - |
$1,536 - kWh |
$11,996 1,150 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4321 UPGRADE OBSOLETE EQUIPMENT |
Savings: $9,337 Cost: $35,560 |
$9,337 | 137,709 | - | - | - | - |
$9,337 137,709 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.1192 REDUCE SCRAP PRODUCTION |
Savings: $4,795 Cost: $10,700 |
$3,779 | 55,742 | $1,016 | 83 | - | - |
$3,779 55,742 kWh |
$1,016 83 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY |
Savings: $3,282 Cost: $9,400 |
$2,895 | 42,702 | $387 | 32 | - | - |
$2,895 42,702 kWh |
$387 32 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY |
Savings: $2,473 Cost: $2,350 |
$1,985 | 29,270 | $488 | 40 | - | - |
$1,985 29,270 kWh |
$488 40 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $88,765 Cost: $309,226 |
$95,703 | 1,388,893 | $30,330 | 2,656 | $(-37,268) | (-10,648) | $95,703 1,388,893 kWh |
$30,330 2,656 kW-months/year |
$(-37,268) (-10,648) MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $33,419 Cost: $157,976 |
$19,532 | 265,423 | $13,887 | 1,306 | - | - | $19,532 265,423 kWh |
$13,887 1,306 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |