Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 2018 |
Principal Product | Corrugated Boxes |
NAICS | 322219 - Other Paperboard Container Manufacturing |
SIC | 2652 - Setup Paperboard Boxes |
Sales | $50,000,000-$100,000,000 |
# of Employees | 134 |
Plant Area (Sq.Ft.) | 460,857 |
Annual Production | 938,435 Units |
Production Hrs. Annual | 6,732 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $486,799 | 7,407,039 | kWh | $0.07 |
Electricity Demand | $433,192 | 17,232 | kW-months/year | $25.14 |
Electricity Fees | $10,781 | - | $ | - |
Natural Gas | $97,325 | 105,222 | MMBtu | $0.92 |
TOTAL ENERGY COSTS | $1,028,097 | |||
RECOMMENDED SAVINGS* | $174,786 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $167,857 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Ancillary Material Cost | Electricity Usage | Electricity Demand | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $100,744 Cost: $336,960 |
$(-3,169) | (-48,232) | $103,913 | 4,133 | - | - |
$(-3,169) (-48,232) kWh |
$103,913 4,133 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $39,996 Cost: $72,976 |
$23,276 | 354,258 | $16,201 | 644 | $519 | - |
$23,276 354,258 kWh |
$16,201 644 kW-months/year |
$519 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $13,413 Cost: $3,068 |
$12,169 | 185,220 | $1,244 | 50 | - | - |
$12,169 185,220 kWh |
$1,244 50 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $11,548 Cost: $4,000 |
$11,548 | 175,773 | - | - | - | - |
$11,548 175,773 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $6,929 Cost: $1,200 |
$6,929 | 105,464 | - | - | - | - |
$6,929 105,464 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $2,156 Cost: $5,358 |
$2,156 | 32,823 | - | - | - | - |
$2,156 32,823 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $174,786 Cost: $423,562 |
$52,909 | 805,306 | $121,358 | 4,827 | $519 | - | $52,909 805,306 kWh |
$121,358 4,827 kW-months/year |
$519 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $167,857 Cost: $422,362 |
$45,980 | 699,842 | $121,358 | 4,827 | $519 | - | $45,980 699,842 kWh |
$121,358 4,827 kW-months/year |
$519 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Ancillary Material Cost | Electricity Usage | Electricity Demand | Ancillary Material Cost |