Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 2023 |
Principal Product | Metal Bellows and Metal Hoses |
NAICS | 332510 - Hardware Manufacturing |
SIC | 3599 - Industrial Machinery, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 85 |
Plant Area (Sq.Ft.) | 54,000 |
Annual Production | 500,000 Units |
Production Hrs. Annual | 4,950 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $111,346 | 488,588 | kWh | $0.23 |
Electricity Demand | $96,573 | 1,661 | kW-months/year | $58.16 |
Electricity Fees | $(-45,866) | - | $ | - |
TOTAL ENERGY COSTS | $162,053 | |||
RECOMMENDED SAVINGS* | $269,965 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $6,654 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Electricity Usage | Electricity Demand | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,805 Cost: $300 |
$1,805 | 7,920 | - | - | - | - |
$1,805 7,920 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3134 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION |
Savings: $28,974 Cost: - |
- | - | $28,974 | 498 | - | - |
- - kWh |
$28,974 498 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,227 Cost: $4,339 |
$1,376 | 6,036 | $851 | 15 | - | - |
$1,376 6,036 kWh |
$851 15 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,654 Cost: $4,172 |
$4,092 | 17,957 | $2,499 | 43 | $63 | - |
$4,092 17,957 kWh |
$2,499 43 kW-months/year |
$63 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $111,629 Cost: $154,568 |
$48,816 | 214,200 | $62,813 | 1,080 | - | - |
$48,816 214,200 kWh |
$62,813 1,080 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $24,771 Cost: $37,377 |
$13,952 | 61,225 | $10,819 | 186 | - | - |
$13,952 61,225 kWh |
$10,819 186 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2625 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE |
Savings: $473 Cost: - |
$267 | 1,172 | $206 | 4 | - | - |
$267 1,172 kWh |
$206 4 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $20,560 Cost: $30,577 |
$11,594 | 50,874 | $8,966 | 154 | - | - |
$11,594 50,874 kWh |
$8,966 154 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.3141 USE BATTERY STORAGE FOR DEMAND CONTROL |
Savings: $72,872 Cost: - |
$(-6,109) | (-26,806) | $78,981 | 1,358 | - | - |
$(-6,109) (-26,806) kWh |
$78,981 1,358 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $269,965 Cost: $231,333 |
$75,793 | 332,578 | $194,109 | 3,337 | $63 | - | $75,793 332,578 kWh |
$194,109 3,337 kW-months/year |
$63 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $6,654 Cost: $4,172 |
$4,092 | 17,957 | $2,499 | 43 | $63 | - | $4,092 17,957 kWh |
$2,499 43 kW-months/year |
$63 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Electricity Usage | Electricity Demand | Personnel Changes |