Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 1995
Principal Product Large Semiconductor Manufacturing Equipment
NAICS n/a
SIC 3559 - Special Industry Machinery, Nec
Sales $10,000,000-$50,000,000
# of Employees 110
Plant Area (Sq.Ft.) 70,198
Annual Production 12 Pieces
Production Hrs. Annual 5,200
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $209,573 2,762,310 kWh $0.08
Natural Gas $9,814 1,570 MMBtu $6.25
TOTAL ENERGY COSTS $219,387
RECOMMENDED SAVINGS* $66,957 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $26,294
#|Description Savings
Cost
Status Electricity Usage Other Liquid (non-haz) Administrative Changes Electricity Usage Other Liquid (non-haz) Administrative Changes
$ kWh $ gal $ $
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$760
Cost:
$2,712
$760 8,792 - - - - $760
8,792
kWh
-
-
gal
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$19,344
Cost:
$77,930
$19,344 249,707 - - - - $19,344
249,707
kWh
-
-
gal
-
-
$
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$216
Cost:
$360
$216 2,931 - - - - $216
2,931
kWh
-
-
gal
-
-
$
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$3,574
Cost:
$6,500
$3,574 59,203 - - - - $3,574
59,203
kWh
-
-
gal
-
-
$
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$2,035
Cost:
$3,560
$2,035 33,118 - - - - $2,035
33,118
kWh
-
-
gal
-
-
$
06: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$8,080
Cost:
$2,950
$8,080 133,646 - - - - $8,080
133,646
kWh
-
-
gal
-
-
$
07: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP Savings:
$2,735
Cost:
$1,768
$2,735 35,756 - - - - $2,735
35,756
kWh
-
-
gal
-
-
$
08: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$2,095
Cost:
$2,297
$2,095 - - - - - $2,095
-
kWh
-
-
gal
-
-
$
09: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL Savings:
$2,400
Cost:
-
- - - - $2,400 - -
-
kWh
-
-
gal
$2,400
-
$
10: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS Savings:
$25,718
Cost:
$644
- - $25,718 2,098 - - -
-
kWh
$25,718
2,098
gal
-
-
$
TOTAL RECOMMENDED Savings:
$66,957
Cost:
$98,721
$38,839 523,153 $25,718 2,098 $2,400 - $38,839
523,153
kWh
$25,718
2,098
gal
$2,400
-
$
TOTAL IMPLEMENTED Savings:
$26,294
Cost:
$87,502
$23,894 320,633 - - $2,400 - $23,894
320,633
kWh
-
-
gal
$2,400
-
$
Savings
Cost
$ kWh $ gal $ $
Electricity Usage Other Liquid (non-haz) Administrative Changes Electricity Usage Other Liquid (non-haz) Administrative Changes