IAC logo
IAC Assessment: SF0088
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SF0088
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 1996
Principal Product Envelopes
NAICS n/a
SIC 2677 - Envelopes
Sales $10,000,000-$50,000,000
# of Employees 117
Plant Area (Sq.Ft.) 85,000
Annual Production 750,000,000 Pieces
Production Hrs. Annual 6,240
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $289,279 3,484,760 kWh $0.08
Electricity Demand $58,710 8,836 kW-months/year $6.64
Natural Gas $9,422 1,408 MMBtu $6.69
TOTAL ENERGY COSTS $373,001
RECOMMENDED SAVINGS* $42,555 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Other Liquid (haz) Solid Waste (non-haz) Electricity Usage Electricity Demand Other Liquid (haz) Solid Waste (non-haz)
$ kWh $ kW-months/year $ gal $ lb
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,890
Cost:
$2,203
$1,522 18,464 $368 56 - - - - $1,522
18,464
kWh
$368
56
kW-months/year
-
-
gal
-
-
lb
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$4,170
Cost:
$2,331
$3,360 40,445 $810 122 - - - - $3,360
40,445
kWh
$810
122
kW-months/year
-
-
gal
-
-
lb
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$13,025
Cost:
$28,020
$10,742 129,250 $2,283 343 - - - - $10,742
129,250
kWh
$2,283
343
kW-months/year
-
-
gal
-
-
lb
04: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$426
Cost:
$1,200
$302 3,517 $124 18 - - - - $302
3,517
kWh
$124
18
kW-months/year
-
-
gal
-
-
lb
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$856
Cost:
$1,382
$766 9,086 $90 13 - - - - $766
9,086
kWh
$90
13
kW-months/year
-
-
gal
-
-
lb
06: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$3,454
Cost:
$1,544
- - $3,454 520 - - - - -
-
kWh
$3,454
520
kW-months/year
-
-
gal
-
-
lb
07: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$1,611
Cost:
$2,106
- - $1,611 - - - - - -
-
kWh
$1,611
-
kW-months/year
-
-
gal
-
-
lb
08: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$214
Cost:
$310
$164 2,052 $50 7 - - - - $164
2,052
kWh
$50
7
kW-months/year
-
-
gal
-
-
lb
09: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$348
Cost:
$1,726
$348 4,103 - - - - - - $348
4,103
kWh
-
-
kW-months/year
-
-
gal
-
-
lb
10: 3.5314 USE IN-PROCESS RECYCLING WHENEVER POSSIBLE Savings:
$13,896
Cost:
-
- - - - - - $13,896 - -
-
kWh
-
-
kW-months/year
-
-
gal
$13,896
-
lb
11: 3.3122 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS Savings:
$2,665
Cost:
$10,550
- - - - $2,665 732 - - -
-
kWh
-
-
kW-months/year
$2,665
732
gal
-
-
lb
TOTAL RECOMMENDED Savings:
$42,555
Cost:
$51,372
$17,204 206,917 $8,790 1,079 $2,665 732 $13,896 - $17,204
206,917
kWh
$8,790
1,079
kW-months/year
$2,665
732
gal
$13,896
-
lb
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
gal
-
-
lb
Savings
Cost
$ kWh $ kW-months/year $ gal $ lb
Electricity Usage Electricity Demand Other Liquid (haz) Solid Waste (non-haz) Electricity Usage Electricity Demand Other Liquid (haz) Solid Waste (non-haz)