Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2010 |
Principal Product | Food Products- Canned Beans & Hominy |
NAICS | 311421 - Fruit and Vegetable Canning |
SIC | 2033 - Canned Fruits And Vegetables |
Sales | $10,000,000-$50,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 250,000 |
Annual Production | 3,600,000 Units |
Production Hrs. Annual | 5,150 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $225,589 | 2,717,938 | kWh | $0.08 |
Electricity Demand | $101,012 | 8,428 | kW-months/year | $11.99 |
Electricity Fees | $22,610 | - | $ | - |
Natural Gas | $617,067 | 125,850 | MMBtu | $4.90 |
TOTAL ENERGY COSTS | $966,278 | |||
RECOMMENDED SAVINGS* | $173,716 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $164,443 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $65,311 Cost: - |
- | - | - | - | $65,311 | 13,780 | - | - |
- - kWh |
- - kW-months/year |
$65,311 13,780 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $806 Cost: - |
$1,166 | 11,133 | - | - | - | - | $(-360) | - |
$1,166 11,133 kWh |
- - kW-months/year |
- - MMBtu |
$(-360) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $450 Cost: - |
$277 | 3,331 | $173 | 14 | - | - | - | - |
$277 3,331 kWh |
$173 14 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2122 INSTALL / REPAIR INSULATION ON CONDENSATE LINES |
Savings: $70,630 Cost: $14,698 |
- | - | - | - | $70,630 | 14,414 | - | - |
- - kWh |
- - kW-months/year |
$70,630 14,414 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $94 Cost: $48 |
$53 | 636 | $41 | 3 | - | - | - | - |
$53 636 kWh |
$41 3 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $6,925 Cost: $4,309 |
$4,490 | 53,941 | $2,435 | 204 | - | - | - | - |
$4,490 53,941 kWh |
$2,435 204 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $8,056 Cost: $11,016 |
- | - | - | - | $8,056 | 1,644 | - | - |
- - kWh |
- - kW-months/year |
$8,056 1,644 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $4,074 Cost: $8,348 |
$2,692 | 32,343 | $1,382 | 120 | - | - | - | - |
$2,692 32,343 kWh |
$1,382 120 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $5,199 Cost: $14,850 |
$2,840 | 34,121 | $2,359 | 204 | - | - | - | - |
$2,840 34,121 kWh |
$2,359 204 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $12,171 Cost: $37,229 |
$7,615 | 91,482 | $4,556 | 384 | - | - | - | - |
$7,615 91,482 kWh |
$4,556 384 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $173,716 Cost: $90,498 |
$19,133 | 226,987 | $10,946 | 929 | $143,997 | 29,838 | $(-360) | - | $19,133 226,987 kWh |
$10,946 929 kW-months/year |
$143,997 29,838 MMBtu |
$(-360) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $164,443 Cost: $67,300 |
$13,601 | 160,523 | $7,205 | 605 | $143,997 | 29,838 | $(-360) | - | $13,601 160,523 kWh |
$7,205 605 kW-months/year |
$143,997 29,838 MMBtu |
$(-360) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes |