Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Stevens Institute of Technology
Assessment Year 1986
Principal Product COMPONENTS FOR ELEC EQUIPMENT
NAICS n/a
SIC 3621 - Motors And Generators
Sales $10,000,000-$50,000,000
# of Employees 199
Plant Area (Sq.Ft.) 0
Annual Production 60,000 Pieces
Production Hrs. Annual 2,000
Location (State) PA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $238,379 3,165,885 kWh $0.08
Natural Gas $26,264 3,208 MMBtu $8.19
TOTAL ENERGY COSTS $264,643
RECOMMENDED SAVINGS* $103,605 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $27,563
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$2,389
Cost:
$1,400
$2,389 31,653 - - $2,389
31,653
kWh
-
-
MMBtu
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,035
Cost:
-
$1,035 13,775 - - $1,035
13,775
kWh
-
-
MMBtu
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$148
Cost:
$100
$148 2,052 - - $148
2,052
kWh
-
-
MMBtu
04: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$63,655
Cost:
$200,000
$111,337 1,479,191 $(-47,682) (-5,938) $111,337
1,479,191
kWh
$(-47,682)
(-5,938)
MMBtu
05: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$12,141
Cost:
$40,000
$21,425 284,584 $(-9,284) (-1,156) $21,425
284,584
kWh
$(-9,284)
(-1,156)
MMBtu
06: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$18,041
Cost:
-
$18,041 239,742 - - $18,041
239,742
kWh
-
-
MMBtu
07: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$5,537
Cost:
$1,000
$5,537 73,564 - - $5,537
73,564
kWh
-
-
MMBtu
08: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$65
Cost:
$200
$65 879 - - $65
879
kWh
-
-
MMBtu
09: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$181
Cost:
$160
$181 2,345 - - $181
2,345
kWh
-
-
MMBtu
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$413
Cost:
-
$413 5,569 - - $413
5,569
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$103,605
Cost:
$242,860
$160,571 2,133,354 $(-56,966) (-7,094) $160,571
2,133,354
kWh
$(-56,966)
(-7,094)
MMBtu
TOTAL IMPLEMENTED Savings:
$27,563
Cost:
$2,500
$27,563 366,355 - - $27,563
366,355
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas