Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2003 |
Principal Product | Turkey Products |
NAICS | 311615 - Poultry Processing |
SIC | 2015 - Poultry Slaughtering And Processing |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 52,000 |
Annual Production | 600,000 Pieces |
Production Hrs. Annual | 4,250 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $148,423 | 2,168,854 | kWh | $0.07 |
Electricity Demand | $76,685 | 6,089 | kW-months/year | $12.59 |
Electricity Fees | $10,972 | - | $ | - |
Fuel Oil #2 | $48,219 | 6,491 | MMBtu | $7.43 |
Other Gas | $9,782 | 1,253 | MMBtu | $7.81 |
TOTAL ENERGY COSTS | $300,081 | |||
RECOMMENDED SAVINGS* | $330,823 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $151,457 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Fuel Oil #2 | Other Gas | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Fuel Oil #2 | Other Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9121 INSTALL WIND POWERED ELECTRIC GENERATOR |
Savings: $141,258 Cost: $1,171,875 |
$64,081 | 2,096,364 | $77,177 | 5,955 | - | - | - | - | - | - | - | - |
$64,081 2,096,364 kWh |
$77,177 5,955 kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $115,419 Cost: $348,540 |
- | - | - | - | - | - | - | - | $115,419 | 14,684 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$115,419 14,684 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $30,000 Cost: $76,518 |
- | - | - | - | - | - | - | - | - | - | $30,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
$30,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $13,096 Cost: $55,580 |
$13,096 | 230,256 | - | - | - | - | - | - | - | - | - | - |
$13,096 230,256 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6121 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED |
Savings: $8,721 Cost: - |
- | - | - | - | - | - | $8,721 | 1,697 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$8,721 1,697 MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.9121 INSTALL WIND POWERED ELECTRIC GENERATOR |
Savings: $7,910 Cost: $10,000 |
$2,606 | 37,225 | $914 | 72 | $4,390 | - | - | - | - | - | - | - |
$2,606 37,225 kWh |
$914 72 kW-months/year |
$4,390 - $ |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.5194 REDESIGN PROCESS |
Savings: $6,861 Cost: $270 |
$4,444 | 63,491 | $2,417 | 191 | - | - | - | - | - | - | - | - |
$4,444 63,491 kWh |
$2,417 191 kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $3,485 Cost: $700 |
- | - | - | - | - | - | $3,485 | 678 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$3,485 678 MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $1,293 Cost: $955 |
- | - | - | - | - | - | $1,293 | 252 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$1,293 252 MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $847 Cost: $1,744 |
$619 | 8,844 | $228 | 18 | - | - | - | - | - | - | - | - |
$619 8,844 kWh |
$228 18 kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $723 Cost: $608 |
$530 | 7,570 | $193 | 15 | - | - | - | - | - | - | - | - |
$530 7,570 kWh |
$193 15 kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $550 Cost: - |
$440 | 6,290 | $110 | 9 | - | - | - | - | - | - | - | - |
$440 6,290 kWh |
$110 9 kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $462 Cost: $29 |
$462 | 6,605 | - | - | - | - | - | - | - | - | - | - |
$462 6,605 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $198 Cost: $150 |
$124 | 1,772 | $74 | 6 | - | - | - | - | - | - | - | - |
$124 1,772 kWh |
$74 6 kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $330,823 Cost: $1,666,969 |
$86,402 | 2,458,417 | $81,113 | 6,266 | $4,390 | - | $13,499 | 2,627 | $115,419 | 14,684 | $30,000 | - | $86,402 2,458,417 kWh |
$81,113 6,266 kW-months/year |
$4,390 - $ |
$13,499 2,627 MMBtu |
$115,419 14,684 MMBtu |
$30,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $151,457 Cost: $408,426 |
$19,591 | 323,056 | $2,948 | 233 | - | - | $13,499 | 2,627 | $115,419 | 14,684 | - | - | $19,591 323,056 kWh |
$2,948 233 kW-months/year |
- - $ |
$13,499 2,627 MMBtu |
$115,419 14,684 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Fuel Oil #2 | Other Gas | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Fuel Oil #2 | Other Gas | Personnel Changes |