IAC logo
IAC Assessment: SU0472
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SU0472
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Syracuse University
Assessment Year 2018
Principal Product Wine
NAICS 312130 - Wineries
SIC 2084 - Wines, Brandy, And Brandy Spirits
Sales $100,000,000-$500,000,000
# of Employees 155
Plant Area (Sq.Ft.) 350,000
Annual Production 20,000 Units
Production Hrs. Annual 6,000
Location (State) NY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $392,042 9,121,642 kWh $0.04
Electricity Demand $259,704 23,651 kW-months/year $10.98
Electricity Fees $63,305 - $ -
Natural Gas $195,496 54,135 MMBtu $3.61
TOTAL ENERGY COSTS $953,547
RECOMMENDED SAVINGS* $50,122 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $33,105
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ MMBtu $ $
01: 4.821 PAY BILLS ON TIME TO AVOID LATE FEES Savings:
$4,715
Cost:
-
- - - - - - $4,715 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$4,715
-
$
02: 2.2123 INSULATE FEEDWATER TANK Savings:
$1,339
Cost:
$6,120
- - - - $1,339 372 - - -
-
kWh
-
-
kW-months/year
$1,339
372
MMBtu
-
-
$
03: 2.7134 USE PHOTOCELL CONTROLS Savings:
$482
Cost:
$265
$482 11,159 - - - - - - $482
11,159
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
04: 2.1336 INSTALL EQUIPMENT TO UTILIZE WASTE FUEL Savings:
$10,224
Cost:
$10,000
- - - - $10,224 2,840 - - -
-
kWh
-
-
kW-months/year
$10,224
2,840
MMBtu
-
-
$
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,377
Cost:
$3,200
$1,377 31,884 - - - - - - $1,377
31,884
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$25,355
Cost:
$47,766
$11,697 270,765 $6,114 557 - - $7,544 - $11,697
270,765
kWh
$6,114
557
kW-months/year
-
-
MMBtu
$7,544
-
$
07: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$208
Cost:
$420
$208 4,818 - - - - - - $208
4,818
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
08: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$6,103
Cost:
$15,784
- - - - $6,103 1,696 - - -
-
kWh
-
-
kW-months/year
$6,103
1,696
MMBtu
-
-
$
09: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$319
Cost:
$1,132
$319 7,392 - - - - - - $319
7,392
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$50,122
Cost:
$84,687
$14,083 326,018 $6,114 557 $17,666 4,908 $12,259 - $14,083
326,018
kWh
$6,114
557
kW-months/year
$17,666
4,908
MMBtu
$12,259
-
$
TOTAL IMPLEMENTED Savings:
$33,105
Cost:
$58,218
$13,393 310,041 $6,114 557 $1,339 372 $12,259 - $13,393
310,041
kWh
$6,114
557
kW-months/year
$1,339
372
MMBtu
$12,259
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost