Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Texas, Arlington |
---|---|
Assessment Year | 2003 |
Principal Product | Corrugated Boxes |
NAICS | 336390 - Other Motor Vehicle Parts Manufacturing |
SIC | 3585 - Refrigeration And Heating Equipment |
Sales | $10,000,000-$50,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 150,000 |
Annual Production | 700,000 Thousand Feet |
Production Hrs. Annual | 6,216 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $192,058 | 4,652,256 | kWh | $0.04 |
Electricity Demand | $56,767 | 9,906 | kW-months/year | $5.73 |
Electricity Fees | $7,526 | - | $ | - |
Natural Gas | $166,317 | 43,355 | MMBtu | $3.84 |
TOTAL ENERGY COSTS | $422,668 | |||
RECOMMENDED SAVINGS* | $39,048 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $36,763 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $12,000 Cost: $24,409 |
$12,000 | 311,733 | - | - | - | - | - | - | - | - |
$12,000 311,733 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.444 INSTALL SYSTEM TO COLLECT SCRAP |
Savings: $6,700 Cost: $82 |
- | - | - | - | - | - | - | - | $6,700 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$6,700 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $6,390 Cost: $1,045 |
- | - | - | - | - | - | $6,390 | 1,665 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$6,390 1,665 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7229 AIR CONDITION ONLY SPACE NECESSARY |
Savings: $6,360 Cost: - |
- | - | - | - | - | - | $6,360 | 1,658 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$6,360 1,658 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,340 Cost: $130 |
$2,690 | 70,480 | $650 | 136 | - | - | - | - | - | - |
$2,690 70,480 kWh |
$650 136 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $1,083 Cost: - |
- | - | - | - | $1,083 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,083 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $750 Cost: - |
$600 | 16,110 | $150 | 31 | - | - | - | - | - | - |
$600 16,110 kWh |
$150 31 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $745 Cost: - |
$545 | 14,255 | $200 | 41 | - | - | - | - | - | - |
$545 14,255 kWh |
$200 41 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $690 Cost: $170 |
- | - | - | - | - | - | $690 | 179 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$690 179 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7122 DISCONNECT BALLASTS |
Savings: $530 Cost: $47 |
$430 | 11,230 | $100 | 21 | - | - | - | - | - | - |
$430 11,230 kWh |
$100 21 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $260 Cost: $250 |
$260 | 6,730 | - | - | - | - | - | - | - | - |
$260 6,730 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.2122 INSTALL / REPAIR INSULATION ON CONDENSATE LINES |
Savings: $200 Cost: $129 |
- | - | - | - | - | - | $200 | 51 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$200 51 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $39,048 Cost: $26,262 |
$16,525 | 430,538 | $1,100 | 229 | $1,083 | - | $13,640 | 3,553 | $6,700 | - | $16,525 430,538 kWh |
$1,100 229 kW-months/year |
$1,083 - $ |
$13,640 3,553 MMBtu |
$6,700 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $36,763 Cost: $25,965 |
$14,690 | 382,213 | $650 | 136 | $1,083 | - | $13,640 | 3,553 | $6,700 | - | $14,690 382,213 kWh |
$650 136 kW-months/year |
$1,083 - $ |
$13,640 3,553 MMBtu |
$6,700 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes |