Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Tennessee |
---|---|
Assessment Year | 1994 |
Principal Product | Industrial and commercial equipment tire retread materials a |
NAICS | n/a |
SIC | 3011 - Tires And Inner Tubes |
Sales | $50,000,000-$100,000,000 |
# of Employees | 180 |
Plant Area (Sq.Ft.) | 80,000 |
Annual Production | 47,500,000 Pounds |
Production Hrs. Annual | 6,120 |
Location (State) | SC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $656,407 | 12,917,937 | kWh | $0.05 |
Natural Gas | $193,765 | 41,215 | MMBtu | $4.70 |
TOTAL ENERGY COSTS | $850,172 | |||
RECOMMENDED SAVINGS* | $226,653 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $25,845 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | Electricity Usage | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | gal | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $10,406 Cost: $28,960 |
- | - | $10,406 | 2,214 | - | - | - | - |
- - kWh |
$10,406 2,214 MMBtu |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $9,687 Cost: $660 |
- | - | $9,687 | 2,061 | - | - | - | - |
- - kWh |
$9,687 2,061 MMBtu |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $5,456 Cost: - |
$5,456 | 106,975 | - | - | - | - | - | - |
$5,456 106,975 kWh |
- - MMBtu |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,556 Cost: $1,248 |
$2,556 | 50,117 | - | - | - | - | - | - |
$2,556 50,117 kWh |
- - MMBtu |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6221 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY |
Savings: $1,943 Cost: - |
$1,943 | 38,101 | - | - | - | - | - | - |
$1,943 38,101 kWh |
- - MMBtu |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,794 Cost: - |
$1,794 | 35,170 | - | - | - | - | - | - |
$1,794 35,170 kWh |
- - MMBtu |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,256 Cost: - |
$1,256 | 24,619 | - | - | - | - | - | - |
$1,256 24,619 kWh |
- - MMBtu |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $1,121 Cost: - |
$1,121 | 21,981 | - | - | - | - | - | - |
$1,121 21,981 kWh |
- - MMBtu |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $315 Cost: $145 |
- | - | $315 | 67 | - | - | - | - |
- - kWh |
$315 67 MMBtu |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $987 Cost: $3,000 |
$987 | 19,343 | - | - | - | - | - | - |
$987 19,343 kWh |
- - MMBtu |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $209 Cost: $179 |
$209 | 4,103 | - | - | - | - | - | - |
$209 4,103 kWh |
- - MMBtu |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $154,581 Cost: $34,400 |
- | - | - | - | - | - | $154,581 | 718,151 |
- - kWh |
- - MMBtu |
- - gal |
$154,581 718,151 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 3.1175 USE A DIFFERENT OR RECYCLED RAW MATERIAL |
Savings: $19,814 Cost: $15,400 |
- | - | - | - | $19,814 | 43,838 | - | - |
- - kWh |
- - MMBtu |
$19,814 43,838 gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $13,077 Cost: $10,000 |
- | - | - | - | - | - | $13,077 | 52,125 |
- - kWh |
- - MMBtu |
- - gal |
$13,077 52,125 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $3,451 Cost: - |
- | - | - | - | - | - | $3,451 | 117,570 |
- - kWh |
- - MMBtu |
- - gal |
$3,451 117,570 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $226,653 Cost: $93,992 |
$15,322 | 300,409 | $20,408 | 4,342 | $19,814 | 43,838 | $171,109 | 887,846 | $15,322 300,409 kWh |
$20,408 4,342 MMBtu |
$19,814 43,838 gal |
$171,109 887,846 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $25,845 Cost: $2,232 |
$12,392 | 242,965 | $10,002 | 2,128 | - | - | $3,451 | 117,570 | $12,392 242,965 kWh |
$10,002 2,128 MMBtu |
- - gal |
$3,451 117,570 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | gal | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | Electricity Usage | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) |