IAC logo
IAC Assessment: UD0429
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UD0429
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Dayton
Assessment Year 1994
Principal Product metal cabinets
NAICS n/a
SIC 2522 - Office Furniture, Except Wood
Sales $1,000,000-$5,000,000
# of Employees 30
Plant Area (Sq.Ft.) 53,800
Annual Production 6,000 Pieces
Production Hrs. Annual 3,000
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $16,814 168,816 kWh $0.10
Natural Gas $9,853 1,950 MMBtu $5.05
TOTAL ENERGY COSTS $26,667
RECOMMENDED SAVINGS* $4,792 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $834
#|Description Savings
Cost
Status Electricity Usage Natural Gas Coal Administrative Changes Electricity Usage Natural Gas Coal Administrative Changes
$ kWh $ MMBtu $ MMBtu $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$585
Cost:
$1,250
$417 4,982 - - - - $168 - $417
4,982
kWh
-
-
MMBtu
-
-
MMBtu
$168
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$249
Cost:
$44
$225 2,931 - - - - $24 - $225
2,931
kWh
-
-
MMBtu
-
-
MMBtu
$24
-
$
03: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$260
Cost:
$500
$428 6,448 $(-168) (-33) - - - - $428
6,448
kWh
$(-168)
(-33)
MMBtu
-
-
MMBtu
-
-
$
04: 2.1332 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS Savings:
$3,500
Cost:
$50,000
- - - - $3,000 857 $500 - -
-
kWh
-
-
MMBtu
$3,000
857
MMBtu
$500
-
$
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$198
Cost:
$240
$198 2,345 - - - - - - $198
2,345
kWh
-
-
MMBtu
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$4,792
Cost:
$52,034
$1,268 16,706 $(-168) (-33) $3,000 857 $692 - $1,268
16,706
kWh
$(-168)
(-33)
MMBtu
$3,000
857
MMBtu
$692
-
$
TOTAL IMPLEMENTED Savings:
$834
Cost:
$1,294
$642 7,913 - - - - $192 - $642
7,913
kWh
-
-
MMBtu
-
-
MMBtu
$192
-
$
Savings
Cost
$ kWh $ MMBtu $ MMBtu $ $
Electricity Usage Natural Gas Coal Administrative Changes Electricity Usage Natural Gas Coal Administrative Changes