Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2001 |
Principal Product | plastic parts |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 54 |
Plant Area (Sq.Ft.) | 66,000 |
Annual Production | 500,000 Pounds |
Production Hrs. Annual | 6,000 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $44,831 | 1,300,320 | kWh | $0.03 |
Electricity Demand | $69,316 | 6,336 | kW-months/year | $10.94 |
Natural Gas | $5,928 | 963 | MMBtu | $6.16 |
TOTAL ENERGY COSTS | $126,771 | |||
RECOMMENDED SAVINGS* | $107,872 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.1192 REDUCE SCRAP PRODUCTION |
Savings: $47,250 Cost: $1,050 |
- | - | - | - | - | - | $47,250 | 52,500 |
- - kWh |
- - kW-months/year |
- - Tgal |
$47,250 52,500 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $32,010 Cost: $101,000 |
$14,605 | 724,800 | $17,405 | 1,704 | - | - | - | - |
$14,605 724,800 kWh |
$17,405 1,704 kW-months/year |
- - Tgal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $13,365 Cost: $1,540 |
$6,600 | 330,000 | $6,765 | 660 | - | - | - | - |
$6,600 330,000 kWh |
$6,765 660 kW-months/year |
- - Tgal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $5,787 Cost: - |
$3,030 | 151,500 | $2,757 | 252 | - | - | - | - |
$3,030 151,500 kWh |
$2,757 252 kW-months/year |
- - Tgal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $3,552 Cost: $430 |
- | - | - | - | $3,552 | 591,747 | - | - |
- - kWh |
- - kW-months/year |
$3,552 591,747 Tgal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $3,378 Cost: $7,000 |
$1,435 | 83,400 | $1,943 | 190 | - | - | - | - |
$1,435 83,400 kWh |
$1,943 190 kW-months/year |
- - Tgal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $1,215 Cost: $4,790 |
$600 | 30,000 | $615 | 60 | - | - | - | - |
$600 30,000 kWh |
$615 60 kW-months/year |
- - Tgal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $486 Cost: - |
$240 | 12,000 | $246 | 24 | - | - | - | - |
$240 12,000 kWh |
$246 24 kW-months/year |
- - Tgal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $427 Cost: $1,473 |
$204 | 10,200 | $223 | 20 | - | - | - | - |
$204 10,200 kWh |
$223 20 kW-months/year |
- - Tgal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $251 Cost: $722 |
$120 | 6,000 | $131 | 12 | - | - | - | - |
$120 6,000 kWh |
$131 12 kW-months/year |
- - Tgal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $151 Cost: $161 |
$72 | 3,600 | $79 | 7 | - | - | - | - |
$72 3,600 kWh |
$79 7 kW-months/year |
- - Tgal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $107,872 Cost: $118,166 |
$26,906 | 1,351,500 | $30,164 | 2,929 | $3,552 | 591,747 | $47,250 | 52,500 | $26,906 1,351,500 kWh |
$30,164 2,929 kW-months/year |
$3,552 591,747 Tgal |
$47,250 52,500 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - Tgal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) |