Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2020 |
Principal Product | Car Seats and Strollers |
NAICS | 336991 - Motorcycle, Bicycle, and Parts Manufacturing |
SIC | 3944 - Games, Toys, and Children's Vehicles, Except Dolls and Bicycles |
Sales | $100,000,000-$500,000,000 |
# of Employees | 350 |
Plant Area (Sq.Ft.) | 360,000 |
Annual Production | 12,872,000 Units |
Production Hrs. Annual | 4,420 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $518,773 | 11,384,100 | kWh | $0.05 |
Electricity Demand | $346,041 | 22,841 | kW-months/year | $15.15 |
Electricity Fees | $504 | - | $ | - |
Natural Gas | $22,145 | 3,595 | MMBtu | $6.16 |
TOTAL ENERGY COSTS | $908,164 | |||
RECOMMENDED SAVINGS* | $129,327 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $103,617 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $10,283 Cost: - |
$6,492 | 142,472 | $3,791 | 250 | - | - | - | - |
$6,492 142,472 kWh |
$3,791 250 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $32,724 Cost: - |
- | - | $32,724 | 2,160 | - | - | - | - |
- - kWh |
$32,724 2,160 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $5,965 Cost: $1,400 |
- | - | - | - | $5,965 | 561 | - | - |
- - kWh |
- - kW-months/year |
$5,965 561 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $8,342 Cost: - |
$6,474 | 142,057 | $2,948 | 194 | - | - | $(-1,080) | - |
$6,474 142,057 kWh |
$2,948 194 kW-months/year |
- - Tgal |
$(-1,080) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $6,841 Cost: - |
$4,700 | 103,148 | $2,141 | 141 | - | - | - | - |
$4,700 103,148 kWh |
$2,141 141 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $4,902 Cost: $2,000 |
$3,368 | 73,911 | $1,534 | 101 | - | - | - | - |
$3,368 73,911 kWh |
$1,534 101 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY |
Savings: $8,594 Cost: $1,590 |
$5,905 | 129,579 | $2,689 | 178 | - | - | - | - |
$5,905 129,579 kWh |
$2,689 178 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $24,419 Cost: $37,053 |
$12,411 | 272,361 | $10,397 | 686 | - | - | $1,611 | - |
$12,411 272,361 kWh |
$10,397 686 kW-months/year |
- - Tgal |
$1,611 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $16,106 Cost: $2,800 |
$7,919 | 173,781 | $7,148 | 472 | - | - | $1,039 | - |
$7,919 173,781 kWh |
$7,148 472 kW-months/year |
- - Tgal |
$1,039 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $10,902 Cost: $7,800 |
$5,852 | 128,422 | $5,330 | 352 | - | - | $(-280) | - |
$5,852 128,422 kWh |
$5,330 352 kW-months/year |
- - Tgal |
$(-280) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $249 Cost: $240 |
$249 | 5,453 | - | - | - | - | - | - |
$249 5,453 kWh |
- - kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $129,327 Cost: $52,883 |
$53,370 | 1,171,184 | $68,702 | 4,534 | $5,965 | 561 | $1,290 | - | $53,370 1,171,184 kWh |
$68,702 4,534 kW-months/year |
$5,965 561 Tgal |
$1,290 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $103,617 Cost: $41,853 |
$41,364 | 907,730 | $60,683 | 4,005 | - | - | $1,570 | - | $41,364 907,730 kWh |
$60,683 4,005 kW-months/year |
- - Tgal |
$1,570 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes |