IAC logo
IAC Assessment: UF0013
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UF0013
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 1991
Principal Product WIRE, BASKETS, SHELVING
NAICS n/a
SIC 3496 - Misc. Fabricated Wire Products
Sales $50,000,000-$100,000,000
# of Employees 430
Plant Area (Sq.Ft.) 0
Annual Production 1,000,000 Pieces
Production Hrs. Annual 6,240
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $447,192 7,072,099 kWh $0.06
Natural Gas $264,603 69,386 MMBtu $3.81
TOTAL ENERGY COSTS $711,795
RECOMMENDED SAVINGS* $89,904 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $89,904
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$27,648
Cost:
$34,850
$27,648 - - - $27,648
-
kWh
-
-
MMBtu
02: 2.3511 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS Savings:
$18,637
Cost:
$34,000
$18,637 - - - $18,637
-
kWh
-
-
MMBtu
03: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$3,117
Cost:
-
$3,117 - - - $3,117
-
kWh
-
-
MMBtu
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$13,964
Cost:
-
$13,964 221,278 - - $13,964
221,278
kWh
-
-
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$8,775
Cost:
$21,477
$8,775 139,215 - - $8,775
139,215
kWh
-
-
MMBtu
06: 2.7123 KEEP LAMPS AND REFLECTORS CLEAN Savings:
$6,364
Cost:
-
$6,364 101,700 - - $6,364
101,700
kWh
-
-
MMBtu
07: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$2,089
Cost:
$1,892
$2,089 33,118 - - $2,089
33,118
kWh
-
-
MMBtu
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$2,841
Cost:
$3,067
$2,841 45,135 - - $2,841
45,135
kWh
-
-
MMBtu
09: 2.7233 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT Savings:
$756
Cost:
$880
$756 12,016 - - $756
12,016
kWh
-
-
MMBtu
10: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$5,713
Cost:
$20,700
- - $5,713 1,499 -
-
kWh
$5,713
1,499
MMBtu
TOTAL RECOMMENDED Savings:
$89,904
Cost:
$116,866
$84,191 552,462 $5,713 1,499 $84,191
552,462
kWh
$5,713
1,499
MMBtu
TOTAL IMPLEMENTED Savings:
$89,904
Cost:
$116,866
$84,191 552,462 $5,713 1,499 $84,191
552,462
kWh
$5,713
1,499
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas