IAC logo
IAC Assessment: UF0066
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UF0066
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 1993
Principal Product Folding Paperboard
NAICS n/a
SIC 2657 - Folding Paperboard Boxes
Sales $10,000,000-$50,000,000
# of Employees 190
Plant Area (Sq.Ft.) 180,000
Annual Production 375,000,000 Pieces
Production Hrs. Annual 6,240
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $264,356 3,927,608 kWh $0.07
TOTAL ENERGY COSTS $264,356
RECOMMENDED SAVINGS* $21,388 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $8,838
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$8,838
Cost:
$2,582
$8,838 131,887 $8,838
131,887
kWh
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$4,191
Cost:
$4,378
$4,191 62,427 $4,191
62,427
kWh
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$2,130
Cost:
$1,852
$2,130 31,946 $2,130
31,946
kWh
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,400
Cost:
$675
$1,400 20,809 $1,400
20,809
kWh
05: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$1,220
Cost:
-
$1,220 - $1,220
-
kWh
06: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$3,609
Cost:
$14,400
$3,609 47,186 $3,609
47,186
kWh
TOTAL RECOMMENDED Savings:
$21,388
Cost:
$23,887
$21,388 294,255 $21,388
294,255
kWh
TOTAL IMPLEMENTED Savings:
$8,838
Cost:
$2,582
$8,838 131,887 $8,838
131,887
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage